Juniper Networks QSFP-100G-CWDM-T2 Compatible 100G QSFP28 Transceiver | 100GBASE-CWDM4 2KM Module 4×25G NRZ Duplex LC SMF
Product Overview
HYTOPTODEVICE 100G QSFP28 CWDM4 transceiver serves as a pin-compatible replacement for Juniper QSFP-100G-CWDM-T2.
It adopts four-channel CWDM wavelength architecture and transmits 100G traffic through 4×25G NRZ modulation.
This transceiver is designed for short-distance interconnections inside data centers.
It delivers stable 100G signal transmission up to 2km using OS2 single-mode fiber.
Duplex LC connectors simplify patch panel layout and routine fiber maintenance tasks.
The design complies with QSFP28 MSA and IEEE industry standards.
Built-in DDM function continuously monitors optical power, operating temperature, supply voltage and laser bias current.
Custom EEPROM coding enables smooth identification on Juniper devices without triggering unauthorized transceiver alarms.
This cost-effective transceiver suits leaf-spine architecture, inter-switch trunk links and ToR switch to server NIC uplinks.
We provide sample evaluation, personalized firmware programming and flexible bulk pricing for system integrators and data center operators.
Key Technical Specifications
| Juniper Compatible |
QSFP-100G-CWDM-T2 |
Vendor Name |
HYTOPTODEVICE |
| Form Factor |
QSFP28 |
Max Data Rate |
103.125Gbps (4x 25.78Gbps) |
| Wavelength |
1271nm, 1291nm, 1311nm and 1331nm
|
Max Distance |
2km |
| Connector |
Duplex LC/UPC |
Transmitter Type |
4 x CWDM DML (DFB) |
| Cable Type |
SMF |
Receiver Type |
PIN |
| Modulation (Electrical) |
4x 25G-NRZ |
TX Power |
-6.5~+2.5dBm |
| Power Consumption |
< 3.5W |
Receiver Sensitivity |
< -11.5dBm |
| Protocols |
QSFP28 MSA, SFF-8636, IEEE 802.3ba, IEEE 802.3bm, CAUI-4 |
Operation Temperature |
0 to 70°C (32 to 158°F) |
For detailed technical specifications, please refer to the Datasheet
Usage Guidelines & Best Practices
1. Fiber Matching: Only support OS2 G.652D single-mode fiber. Multimode fiber cannot meet 2km transmission requirements and will cause signal attenuation or link down.
2. Port Configuration: Enable RS-FEC function on switch ports to guarantee error-free and stable full-distance 2km transmission.
3. Installation Specification: Support hot-plug operation. Insert and pull out modules gently to avoid pin damage; reserve bending space for fiber cables.
4. Scenario Restriction: This module is designed for 2km medium-distance transmission. For links over 2km, please choose 100G LR4 long-distance modules.
5. Operating Environment: Work stably at 0°C~70°C commercial temperature. Avoid high temperature, humid and dusty harsh environment for long-term operation.
For detailed operation instructions, please refer to the User Guide.
Full Compatibility List & Supported Network Hardware
1. Supported Hardware & Firmware
This CWDM4 transceiver is pre-programmed with Juniper matching identification information.
It supports plug-and-play deployment on validated Juniper hardware platforms.
It avoids persistent alarm prompts, unstable link negotiation and intermittent link flapping under mainstream Junos OS firmware releases.
Validated Juniper Device Models:
- Juniper QFX5100, QFX5120 Data Center Switches
- Juniper EX4600 Enterprise Core Switches
- Juniper QFX10000 High-Density 100G Leaf-Spine Switch Series
- All Juniper platforms equipped with standard QSFP28 100G ports
2.Cross-Brand Compatibility
The transceiver follows universal QSFP28 MSA specifications.
It supports interconnection with Cisco, Huawei, Aruba, H3C and other brand equipment within multi-vendor network environments.
It fits gradual network upgrade projects and hybrid data center expansion plans.
3.Free Value-Added Services
We offer free EEPROM rewriting and private label customization.
Pre-shipment sample validation and dedicated engineering support are available.
Large-volume orders qualify for tiered pricing to reduce overall data center hardware expenditure.
Primary Application Scenarios
- Data Center Leaf-Spine Fabric: Short-distance 100G interconnections for Juniper Junos OS based data center architectures.
- Inter-Switch Trunk Upgrade: Bandwidth expansion between core and aggregation switch layers.
- Switch-to-Server Uplink: High-capacity connections from ToR switches to server and storage NICs.
- Intra-Campus Short Links: Single-mode fiber connections within one data center or campus building.
- Hybrid Multi-Vendor Fabric: Cost-effective 100G links deployed in mixed Juniper and third-party switch environments.
Connectivity Solutions(Applications)
1.Leaf-Spine Architecture

2. 100G to 100G for Switch-Switch Interconnection

3.100G to 100G for Switch-NIC Connection

The Core Feature
1.Low Power and High-Density Realize 100G Connectivity for Data Center
Ultra-low 3.5W max power consumption reduces data center power loss and PUE. Compact QSFP28 design supports high-density port deployment, realizing efficient 100G high-speed data center transmission.

2.Verified Host Interoperability
All modules pass real target device interoperability tests. Matched EEPROM ensures zero-alarm hot-swap and stable long-term operation on mainstream platforms.
Specific Compatibility Video available upon request.

3.Strict Full-Round Quality Testing
Every module undergoes optical calibration, wide temperature cycling,aging burn-in and BER testing. Strict quality control guarantees stable 24/7 commercial operation.Curious how? Tour the
Test Center.

FAQ
Q1: Can CWDM4 run over multimode fiber (OM3/OM4)?
A1: Standard 100G CWDM4 is engineered exclusively for OS2 single-mode fiber. OM3 and OM4 multimode fiber cannot transmit the specific CWDM wavelength grid properly, resulting in link negotiation failure or unstable connectivity. Our Juniper QSFP-100G-CWDM-T2 compatible transceiver strictly follows single-mode design standards to prevent improper fiber deployment errors.
Q2: Why is CWDM4 rated for 2km, but sometimes fails beyond 500m or 1km?
A2: The 2km rating is calculated under ideal conditions with clean OS2 fiber, premium connectors and minimal splice loss. Contaminated fiber end faces, low-grade patch cords, excessive splice joints or mismatched APC/UPC interfaces rapidly consume available optical budget. Our factory tests every CWDM4 transceiver under realistic loss conditions to reduce unexpected field link faults.
Q3: Can I connect a 100G CWDM4 on one end and a 100G LR4 on the other?
A3: CWDM4 and LR4 adopt different wavelength grids and signal modulation structures, so stable interworking cannot be realized. A normal 100G link cannot be established. We recommend deploying our matched Juniper compatible CWDM4 transceivers on both ends of the fiber path to achieve consistent link performance.
Q4: Will a Brand A CWDM4 module link up with a Brand B CWDM4 module?
A4: Cross-brand CWDM4 interworking cannot be fully guaranteed even with identical wavelength channels. Differences in transmit optical power, receiver sensitivity and internal firmware logic may trigger intermittent link drops. Our QSFP-100G-CWDM-T2 compatible transceivers maintain tight optical parameter tolerances to deliver predictable end-to-end link performance.
Q5: What is the maximum allowed optical loss (power budget) for a link?
A5: Typical power budget of 100G CWDM4 is roughly 4.5 dB. Total loss generated by fiber, connectors and splices must stay below this threshold. Our official datasheets include clear power budget references, and our engineering team can offer quick link loss calculation support before you deploy the network.
Q6: The module feels very hot to the touch. Is this normal?
A6: Mild warmth during regular operation is acceptable, yet obvious overheating usually stems from insufficient rack ventilation or dense port installation. Our CWDM4 transceivers adopt optimized thermal design and stable power control to stabilize operating temperature and cut long-term failure risks inside densely populated racks.
Q7: What are the risks behind unusually cheap CWDM4 modules?
A7: Extremely low-cost transceivers often use unqualified optical chips, skip complete calibration procedures and carry unstable EEPROM programming. They frequently trigger switch alarms, produce high bit error rates and face premature failure. Our factory completes full optical and compatibility testing, offering competitive pricing without skipping critical quality control processes.
Q8: How should I sample-test a bulk shipment of CWDM4 transceivers?
A8: Valid sampling inspection needs DDM data verification, error-free traffic testing at rated distance and compatibility verification on your target switch model. We can supply reference test environments and operation procedures. Every batch shipped from our factory contains relevant test records, and we support pre-shipment sample evaluation for bulk purchasers.
Q9: What should I do if a module freezes or stops responding on the switch?
A9: Re-seat the transceiver first and check fiber cleanliness and port configuration parameters. Confirm your switch firmware supports this transceiver model and FEC settings are consistent at both ends. If the fault persists, our technical support team helps locate coding or hardware defects and provides fast replacement solutions for defective goods.
Q10: What precautions are needed in high-humidity or coastal environments?
A10: Coastal and high-humidity environments demand regular anti-corrosion maintenance for connectors, sealed patch panels and frequent end-face cleaning to avoid salt contamination and metal oxidation. Our transceivers use sturdy metal housings and stable internal components, while proper cable management and dust caps remain necessary to extend service life.
Packaging & Custom OEM Solutions
-
ESD Protection & Fast Shipping: Every module is sealed in an ESD-safe bag and ready for same-day dispatch from stock.
-
Custom OEM & Branding: We provide logo printing, private labeling, and custom packaging to help distributors and integrators build their brand—no factory investment required.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
- Up to 70% cost savings vs OEM, transparent pricing & flexible bulk rates, supported quality returns
- 100% real-device compatible with Cisco, Huawei,Dell,Juniper, and Arista
- ISO 9001:2015 Shenzhen factory, full lineup: 1.25G/10G/25G/40G/100G/200G/400G/800G/1.6T transceivers
- Ample stock, fast global DHL/FedEx shipping in 3–5 working days
- Free pre-sales engineering support for custom EEPROM & private label firmware
- Real switch test videos available for pre-purchase review; inspection & shipping videos provided per order
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
-
ISO 9001: Certified quality management and production consistency.
-
CE & FCC: Fully compliant for seamless Global Market Access.
-
RoHS: Committed to environmental responsibility and hazardous material control.
-
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.

Rigorous Industrial Product Testing

100% 3rd Party Compatible

Partial Test Demonstration

