• H3C QSFP-100G-CWDM4-SM1300 compatible 100G QSFP28 transceiver, 1300nm WDM single mode 2km module
  • 100G QSFP28  2KM optical module with DDM digital diagnostic monitoring
  • 100G QSFP28 duplex LC transceiver for H3C data center switch interconnection
  • H3C QSFP-100G-CWDM4-SM1300 Compatible 100G QSFP28 Transceiver | 1310nm(CWDM4) 2KM Module Bulk Wholesale | HYTOPTODEVICE
  • H3C QSFP-100G-CWDM4-SM1300 compatible 100G QSFP28 transceiver, 1300nm WDM single mode 2km module
  • 100G QSFP28  2KM optical module with DDM digital diagnostic monitoring
  • 100G QSFP28 duplex LC transceiver for H3C data center switch interconnection
  • H3C QSFP-100G-CWDM4-SM1300 Compatible 100G QSFP28 Transceiver | 1310nm(CWDM4) 2KM Module Bulk Wholesale | HYTOPTODEVICE

H3C QSFP-100G-CWDM4-SM1300 Compatible 100G QSFP28 Transceiver | 1310nm(CWDM4) 2KM Module Bulk Wholesale | HYTOPTODEVICE

H3C QSFP-100G-CWDM4-SM1300 compatible 100G QSFP28  transceiver with 4×25G NRZ signaling. CWDM4 wavelengths 1271/1291/1311/1331nm, 2km OS2 single-mode fiber reach via LC Duplex connector, DDM monitoring, plug-and-play for H3C switches. Reliable bulk supply for data center leaf-spine network upgrades. Small sample testing, private labeling, custom EEPROM coding and OEM available for project engineers, distributors and importers.
NO. Brand  Compatible P/N Transceiver Type
1 Cisco  QSFP-100G-CWDM4-S    QSFP28-100G-SR4 
2 Arista Networks  QSFP-100G-CWDM4 QSFP28-100G-PSM4
3 Brocade  100G-QSFP28-CWDM4-2KM QSFP28-100G-LR4
4 Dell  Q28-100G-CWDM4 QSFP28-100G-ER4L
5 H3C  QSFP-100G-CWDM4-SM1300 QSFP28-100G-ZR4
6 HPE Aruba  R0Z30A  QSFP28-100G-DR
7 Huawei  QSFP-100G-CWDM4 QSFP28-100G-FR
8 Juniper Networks  QSFP-100G-CWDM-T2  QSFP28-100G-LR
9 NVIDIA(Mellanox)  MMA1L30-CM 
Description

H3C QSFP-100G-CWDM4-SM1300 Compatible 100G QSFP28 Transceiver | 100GBASE-CWDM4 2KM Module 4×25G NRZ SMF |HYTOPTODEVICE


Product Overview

HYTOPTODEVICE 100G QSFP28 CWDM4 transceiver serves as pin-compatible replacement for H3C QSFP-100G-CWDM4-SM1300.
It adopts four-channel CWDM architecture centered on 1300nm wavelength grid, transmitting 100G traffic via 4×25G NRZ modulation.
This module targets short-to-medium reach data center interconnections. It delivers stable transmission up to 2km over OS2 single-mode fiber.
Duplex LC interface simplifies patch panel deployment and daily fiber management.
It complies with IEEE and QSFP28 MSA standards. Built-in DDM continuously monitors optical power, temperature, voltage and laser bias.
Custom EEPROM firmware enables smooth identification on H3C equipment without unauthorized module alarms.
This affordable transceiver fits leaf-spine fabric, inter-switch trunking and top-of-rack switch to server NIC uplinks.
We provide pre-production sample testing, customized firmware and flexible bulk pricing for system integrators and data center operators.

Key Technical Specifications

H3C Compatible QSFP-100G-CWDM4-SM1300 Vendor Name HYTOPTODEVICE
Form Factor QSFP28 Max Data Rate 103.125Gbps (4x 25.78Gbps)
Wavelength 1271nm, 1291nm, 1311nm and 1331nm
Max Distance 2km
Connector Duplex LC/UPC Transmitter Type 4 x CWDM DML (DFB)
Cable Type SMF Receiver Type PIN
Modulation (Electrical) 4x 25G-NRZ TX Power -6.5~+2.5dBm
Power Consumption < 3.5W Receiver Sensitivity < -11.5dBm
Protocols QSFP28 MSA, SFF-8636, IEEE 802.3ba, IEEE 802.3bm, CAUI-4 Operation Temperature 0 to 70°C (32 to 158°F)

For detailed technical specifications, please refer to the
Datasheet


Usage Guidelines & Best Practices

1. Fiber Matching: Only support OS2 G.652D single-mode fiber. Multimode fiber cannot meet 2km transmission requirements and will cause signal attenuation or link down.
2. Port Configuration: Enable RS-FEC function on switch ports to guarantee error-free and stable full-distance 2km transmission.
3. Installation Specification: Support hot-plug operation. Insert and pull out modules gently to avoid pin damage; reserve bending space for fiber cables.
4. Scenario Restriction: This module is designed for 2km medium-distance transmission. For links over 2km, please choose 100G LR4 long-distance modules.
5. Operating Environment: Work stably at 0°C~70°C commercial temperature. Avoid high temperature, humid and dusty harsh environment for long-term operation.

For detailed operation instructions, please refer to the User Guide.


Full Compatibility List & Supported Network Hardware

1. Supported Hardware & Firmware

This LR4L WDM transceiver is preloaded with H3C-specific identification firmware.
It runs plug-and-play on validated H3C platforms and avoids persistent alarms, unstable negotiation or periodic link flaps across mainstream OS versions.
Validated H3C Device Models:
  • H3C S6850, S6860 Data Center Switches
  • H3C S5570, S5170 Enterprise Core Switches
  • H3C S9850 High-Density 100G Leaf-Spine Switches
  • All H3C platforms with standard QSFP28 100G ports

2.Cross-Brand Compatibility

The module complies with generic QSFP28 MSA standards.
It can interconnect with equipment from Cisco, Dell, Huawei and other vendors in multi-brand fabrics.
It works well during phased network refresh and hybrid infrastructure expansion.

3.Free Value-Added Services

We offer free EEPROM rewriting and private label customization.
Pre-shipment sample validation and dedicated engineering support are available.
Large-volume orders qualify for tiered pricing to reduce overall data center hardware expenditure.

Primary Application Scenarios

  • Data Center Leaf-Spine Uplinks: Medium-range 100G interconnections between H3C leaf and spine switches.
  • Core Aggregation Trunk Upgrade: Bandwidth expansion for enterprise and colocation core layers.
  • Campus Inter-Building Links: 2km single-mode connections across campus buildings or colocation floors.
  • Server Aggregation Farm: High-capacity uplinks from top-of-rack switches to central aggregation nodes.
  • Hybrid Multi-Vendor Fabric: Cost-effective 100G links in mixed H3C and third-party switch environments.

Connectivity Solutions(Applications)

1.Leaf-Spine Architecture


100G CWDM4 QSFP28 transceiver for AMPCon-DC management platform leaf-spine data center fabric architecture



2. 100G to 100G for Switch-Switch Interconnection

100G to 100G switch-to-switch trunk link with Cisco compatible QSFP-100G-CWDM4-S transceive

3.100G to 100G for Switch-NIC Connection

100G switch to server adapter card high-speed connection QSFP28 CWDM4 optical module for data center


The Core Feature 

1.Low Power and High-Density Realize 100G Connectivity for Data Center

Ultra-low 3.5W max power consumption reduces data center power loss and PUE. Compact QSFP28 design supports high-density port deployment, realizing efficient 100G high-speed data center transmission.

2.Verified Host Interoperability

All modules pass real target device interoperability tests. Matched EEPROM ensures zero-alarm hot-swap and stable long-term operation on mainstream platforms. Specific Compatibility Video available upon request.

Full round quality tested 100G CWDM4 QSFP28 module 24/7 stable operation


3.
Strict Full-Round Quality Testing

Every module undergoes optical calibration, wide temperature cycling,aging burn-in and BER testing. Strict quality control guarantees stable 24/7 commercial operation.Curious how? Tour the Test Center.

Full round quality tested 100G CWDM4 QSFP28 module 24/7 stable operation



FAQ

Q1: When to choose 100G CWDM4 instead of standard LR4 for H3C deployments?
A1: Our H3C compatible CWDM4 module suits links up to 2km. It delivers sufficient margin for intra-data center and short campus routes without the extra cost of longer-reach LR4. For same-facility leaf-spine and server uplink layouts, it balances performance and budget well.

Q2: Why is RS-FEC recommended for 100G CWDM4 links?
A2: CWDM4 runs on a tight optical budget. RS-FEC compensates for connector loss, splice variation and minor fiber aging. Enabling FEC helps maintain error-free transmission close to the 2km limit and reduces random packet loss in production.

Q3: Can this 100G QSFP28 CWDM4 module operate in 4×25G breakout mode?
A3: This standard CWDM4 transceiver works in native 100G mode only. It cannot break out into four independent 25G channels. If your design requires 4×25G breakout, pick dedicated breakout QSFP28 models.

Q4: How to handle module alarms across H3C, Cisco or Huawei switches?
A4: Most alarms come from mismatched EEPROM identification. Our modules ship with H3C-specific firmware and support free re-programming for other platforms. We perform real-switch validation to achieve clean plug-and-play deployment.

Q5: Why do DDM wavelength readings deviate slightly from nominal 1300nm CWDM grid?
A5: Minor wavelength offset falls within MSA standard tolerance. All our modules are calibrated and screened before
shipment. Small DDM drift will not affect throughput or link stability under normal H3C operating conditions.

Q6: Do I need an optical attenuator for very short patch cord runs?
A6: Attenuators are usually unnecessary for short patch connections. Our transmit power is tuned for typical data center patch panels. Only extreme over-power scenarios causing repeated errors require an attenuator after checking module specs.

Q7: Rx power remains low after fiber cleaning. What should I check next?
A7: Inspect ferrules for scratches and cables for tight bends or crushed ducts. Swap patch cords and test alternative ports to isolate the fault. If low power follows the module, our engineering team can conduct optical testing and support bulk customers.

Q8: What does DOM Rx power close to -40dBm mean?
A8: Near -40dBm generally indicates no optical signal reaches the receiver. Common causes include disconnected fiber, damaged jumpers or inactive remote transmitter. We provide structured fault isolation steps to restore data center traffic quickly.

Q9: Is there a reliability gap between third-party compatible modules and original H3C OEM transceivers?
A9: Qualified compatible modules can match OEM performance. Our H3C CWDM4 modules use industrial chips and complete optical plus compatibility testing. The real difference lies in vendor lock-in and support contracts, not basic transmission stability.

Q10: What compliance documents should purchasers request from optical module suppliers?
A10: As a professional manufacturer, we provide RoHS certificates, MSA compliance statements, temperature cycle test records and real-switch compatibility reports. All products support traceability to meet enterprise and data center project compliance requirements.


Packaging & Custom OEM Solutions

 

  • ESD Protection & Fast Shipping: Every module is sealed in an ESD-safe bag and ready for same-day dispatch from stock.

  • Custom OEM & Branding: We provide logo printing, private labeling, and custom packaging to help distributors and integrators build their brand—no factory investment required.

HYTOPTODEVICE 10Gbase-bx bidi transceiver  custom packaging


Why Network Engineers Choose HYTOPTODEVICE


HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.

  • Up to 70% cost savings vs OEM, transparent pricing & flexible bulk rates, supported quality returns
  • 100% real-device compatible with Cisco, Huawei,Dell,Juniper, and Arista
  • ISO 9001:2015 Shenzhen factory, full lineup: 1.25G/10G/25G/40G/100G/200G/400G/800G/1.6T transceivers
  • Ample stock, fast global DHL/FedEx shipping in 3–5 working days
  • Free pre-sales engineering support for custom EEPROM  & private label firmware
  • Real switch test videos available for pre-purchase review; inspection & shipping videos provided per order


“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia


Quality Certification & Compliance

 At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.

We adhere to rigorous standards for our SFP modules and network solutions:

  • ISO 9001: Certified quality management and production consistency.

  • CE & FCC: Fully compliant for seamless Global Market Access.

  • RoHS: Committed to environmental responsibility and hazardous material control.

  • Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.

Certified Quality. Global Standards. Guaranteed Performance.




Rigorous Industrial Product Testing

   hytoptodevice check device and equiptment for optical transceiver module

100% 3rd Party Compatible
hytoptodevice 100g qsfp28 sr4 replacement
Partial Test Demonstration
hytoptodevice compatible optical transceiver module for ethernet,data center


  • H3C QSFP-100G-CWDM4-SM1300 compatible 100G QSFP28 transceiver, 1300nm WDM single mode 2km module
  • 100G QSFP28  2KM optical module with DDM digital diagnostic monitoring
  • 100G QSFP28 duplex LC transceiver for H3C data center switch interconnection
  • H3C QSFP-100G-CWDM4-SM1300 Compatible 100G QSFP28 Transceiver | 1310nm(CWDM4) 2KM Module Bulk Wholesale | HYTOPTODEVICE

Download