• H3C QSFP-100G-CWDM4-SM1300 compatible 100G QSFP28 transceiver, 1300nm WDM single mode 10km module
  • 100G QSFP28  2KM optical module with DDM digital diagnostic monitoring
  • 100G QSFP28 duplex LC transceiver for H3C data center switch interconnection
  • NVIDIA(Mellanox)  MMA1L30-CM  Compatible 100G QSFP28 Transceiver | 100GBASE-CWDM4 2KM Module Bulk Wholesale | HYTOPTODEVICE
  • H3C QSFP-100G-CWDM4-SM1300 compatible 100G QSFP28 transceiver, 1300nm WDM single mode 10km module
  • 100G QSFP28  2KM optical module with DDM digital diagnostic monitoring
  • 100G QSFP28 duplex LC transceiver for H3C data center switch interconnection
  • NVIDIA(Mellanox)  MMA1L30-CM  Compatible 100G QSFP28 Transceiver | 100GBASE-CWDM4 2KM Module Bulk Wholesale | HYTOPTODEVICE

NVIDIA(Mellanox)  MMA1L30-CM  Compatible 100G QSFP28 Transceiver | 100GBASE-CWDM4 2KM Module Bulk Wholesale | HYTOPTODEVICE

NVIDIA(Mellanox) MMA1L30-CM compatible 100G QSFP28 CWDM4 transceiver, 4×25G NRZ, 2km over OS2 single-mode fiber, DDM diagnostic support. Fully tested for NVIDIA Quantum switches and ConnectX adapters, ideal for EDR InfiniBand and 100G Ethernet leaf-spine deployments. Small sample testing, private labeling, custom EEPROM coding and OEM available.
NO. Brand  Compatible P/N Transceiver Type
1 Cisco  QSFP-100G-CWDM4-S    QSFP28-100G-SR4 
2 Arista Networks  QSFP-100G-CWDM4 QSFP28-100G-PSM4
3 Brocade  100G-QSFP28-CWDM4-2KM QSFP28-100G-LR4
4 Dell  Q28-100G-CWDM4 QSFP28-100G-ER4L
5 H3C  QSFP-100G-CWDM4-SM1300 QSFP28-100G-ZR4
6 HPE Aruba  R0Z30A  QSFP28-100G-DR
7 Huawei  QSFP-100G-CWDM4 QSFP28-100G-FR
8 Juniper Networks  QSFP-100G-CWDM-T2  QSFP28-100G-LR
9 NVIDIA(Mellanox)  MMA1L30-CM 
Description

NVIDIA(Mellanox)  MMA1L30-CM Compatible 100G QSFP28 Transceiver | 4×25G NRZ, 2km Single Mode Fiber Module Duplex LC/UPC SMF


Product Overview

HYTOPTODEVICE 100G QSFP28 CWDM4 transceiver serves as a fully pin-compatible replacement for NVIDIA(Mellanox) MMA1L30-CM.
It leverages four-channel CWDM wavelength multiplexing and delivers 100G traffic via 4×25G NRZ signaling.
This optical transceiver targets short-reach data center interconnections and supports both 100GbE and EDR InfiniBand workloads.
It maintains stable 100G transmission up to 2km over standard OS2 single-mode fiber.
Duplex LC/UPC interfaces simplify fiber routing inside patch panels and server racks.
The module adheres to QSFP28 MSA and IEEE specifications.
Built-in DDM monitoring continuously tracks optical power, temperature, supply voltage and laser bias current.
Custom-tuned EEPROM profiles allow smooth detection on NVIDIA hardware without unauthorized transceiver alarms.
This flexible solution fits leaf-spine fabric, inter-switch trunk links and ToR uplinks to ConnectX series network adapters.
We provide pre-sample validation, customized firmware coding and scalable bulk pricing for HPC operators and system integrators.

Key Technical Specifications

NVIDIA(Mellanox)  Compatible   MMA1L30-CM Vendor Name HYTOPTODEVICE
Form Factor QSFP28 Max Data Rate 103.125Gbps (4x 25.78Gbps)
Wavelength 1271nm, 1291nm, 1311nm and 1331nm
Max Distance 2km
Connector Duplex LC/UPC Transmitter Type 4 x CWDM DML (DFB)
Cable Type SMF Receiver Type PIN
Modulation (Electrical) 4x 25G-NRZ TX Power -6.5~+2.5dBm
Power Consumption < 3.5W Receiver Sensitivity < -11.5dBm
Protocols QSFP28 MSA, SFF-8636, IEEE 802.3ba, IEEE 802.3bm, CAUI-4 Operation Temperature 0 to 70°C (32 to 158°F)

For detailed technical specifications, please refer to the
Datasheet


Usage Guidelines & Best Practices

1. Fiber Matching: Only support OS2 G.652D single-mode fiber. Multimode fiber cannot meet 2km transmission requirements and will cause signal attenuation or link down.
2. Port Configuration: Enable RS-FEC function on switch ports to guarantee error-free and stable full-distance 2km transmission.
3. Installation Specification: Support hot-plug operation. Insert and pull out modules gently to avoid pin damage; reserve bending space for fiber cables.
4. Scenario Restriction: This module is designed for 2km medium-distance transmission. For links over 2km, please choose 100G LR4 long-distance modules.
5. Operating Environment: Work stably at 0°C~70°C commercial temperature. Avoid high temperature, humid and dusty harsh environment for long-term operation.

For detailed operation instructions, please refer to the User Guide.

 

    Full Compatibility List & Supported Network Hardware

    1. Supported Hardware & Firmware

    This CWDM4 transceiver is pre-programmed with accurate NVIDIA identification data.
    It enables plug-and-play deployment on validated NVIDIA platforms and avoids persistent alarm messages under mainstream firmware releases.
    Validated NVIDIA(Mellanox) Device Models:
    • NVIDIA SN2410, SN2700 Ethernet Switches
    • NVIDIA Quantum EDR InfiniBand Switches
    • ConnectX-5, ConnectX-6 Series 100G Network Adapters
    • All NVIDIA hardware with standard QSFP28 100G ports

    2.Cross-Brand Compatibility

    The module complies with generic QSFP28 MSA standards.
    It can interconnect with equipment from Cisco, Dell, Huawei and other vendors in multi-brand fabrics.
    It works well during phased network refresh and hybrid infrastructure expansion.

    3.Free Value-Added Services

    We offer free EEPROM rewriting and private label customization.
    Pre-shipment sample validation and dedicated engineering support are available.
    Large-volume orders qualify for tiered pricing to reduce overall data center hardware expenditure.

    Primary Application Scenarios

    • Data Center Leaf-Spine Fabric: Short-distance 100G interconnections for NVIDIA Quantum and SN series data center architectures.
    • Inter-Switch Trunk Upgrade: Bandwidth expansion between core and aggregation switch layers.
    • Switch-to-Server Uplink: High-capacity connections from ToR switches to ConnectX server and storage NICs.
    • EDR InfiniBand Interconnect: Reliable short-range links for HPC clusters and high-performance computing environments.
    • Hybrid Multi-Vendor Fabric: Cost-effective 100G links deployed in mixed NVIDIA and third-party switch environments.

    Connectivity Solutions(Applications)

    1.Leaf-Spine Architecture


    100G CWDM4 QSFP28 transceiver for AMPCon-DC management platform leaf-spine data center fabric architecture



    2. 100G to 100G for Switch-Switch Interconnection

    100G to 100G switch-to-switch trunk link with Cisco compatible QSFP-100G-CWDM4-S transceive

    3.100G to 100G for Switch-NIC Connection

    100G switch to server adapter card high-speed connection QSFP28 CWDM4 optical module for data center


    The Core Feature 

    1.Low Power and High-Density Realize 100G Connectivity for Data Center

    Ultra-low 3.5W max power consumption reduces data center power loss and PUE. Compact QSFP28 design supports high-density port deployment, realizing efficient 100G high-speed data center transmission.

    2.Verified Host Interoperability

    All modules pass real target device interoperability tests. Matched EEPROM ensures zero-alarm hot-swap and stable long-term operation on mainstream platforms. Specific Compatibility Video available upon request.

    Full round quality tested 100G CWDM4 QSFP28 module 24/7 stable operation


    3.
    Strict Full-Round Quality Testing

    Every module undergoes optical calibration, wide temperature cycling,aging burn-in and BER testing. Strict quality control guarantees stable 24/7 commercial operation.Curious how? Tour the Test Center.

    Full round quality tested 100G CWDM4 QSFP28 module 24/7 stable operation



    FAQ

    Q1: Can CWDM4 run over multimode fiber (OM3/OM4)?
    A1: Standard 100G CWDM4 is engineered exclusively for OS2 single-mode fiber. OM3 and OM4 multimode fiber cannot transmit the required CWDM wavelength grid, which results in failed negotiation or intermittent connectivity. Our NVIDIA MMA1L30-CM compatible transceiver strictly follows single-mode design rules to prevent incorrect fiber deployment.

    Q2: Why is CWDM4 rated for 2km, but sometimes fails beyond 500m or 1km?
    A2: The 2km rating assumes clean fiber, quality connectors and minimal splice loss. Contaminated end faces, low-grade patch cords, excessive splices or mismatched connector types rapidly consume optical budget. Our factory validates each transceiver under realistic loss conditions to reduce unexpected field failures.

    Q3: Can I connect a 100G CWDM4 on one end and a 100G LR4 on the other?
    A3: CWDM4 and LR4 use different wavelength plans and signal architectures, so reliable interoperability cannot be achieved. A stable 100G link cannot be established. We recommend using our matching NVIDIA compatible CWDM4 transceivers on both ends of the fiber path for consistent performance.

    Q4: Will a Brand A CWDM4 module link up with a Brand B CWDM4 module?
    A4: Cross-brand CWDM4 interoperability cannot be fully guaranteed even with matching wavelength channels. Differences in transmit power, receiver sensitivity and internal firmware may trigger random link drops. Our MMA1L30-CM compatible transceivers maintain tight optical tolerances for predictable end-to-end links.

    Q5: What is the maximum allowed optical loss (power budget) for a link?
    A5: Typical 100G CWDM4 power budget is approximately 4.5 dB. Total loss from fiber, connectors and splices must remain under this threshold. Our datasheets include clear budget references, and our engineering team can assist with quick link loss calculation before network deployment.

    Q6: The module feels very hot to the touch. Is this normal?
    A6: Mild warmth during regular operation is acceptable, yet obvious overheating usually stems from insufficient rack airflow or densely packed ports. Our CWDM4 transceivers adopt refined thermal design and stable power control to stabilize operating temperature and lower long-term failure risk.

    Q7: What are the risks behind unusually cheap CWDM4 modules?
    A7: Extremely low-cost transceivers often use unqualified optical chips, skip complete calibration and carry unstable EEPROM programming. They frequently trigger switch alarms, generate high bit error rates and suffer premature failure. Our factory performs full optical and compatibility testing, offering competitive pricing without skipping critical quality checks.

    Q8: How should I sample-test a bulk shipment of CWDM4 transceivers?
    A8: Effective sampling requires DDM data verification, error-free traffic testing at rated distance and compatibility validation on your target NVIDIA hardware. We can supply reference test environments and operation procedures. Every batch shipped from our factory contains relevant test records, and we support pre-shipment sample evaluation for bulk purchasers.

    Q9: What should I do if a module freezes or stops responding on the switch?
    A9: Reseat the transceiver first and inspect fiber cleanliness and port configuration parameters. Confirm your switch firmware supports this transceiver model and FEC settings match on both ends. If the fault persists, our technical team helps locate coding or hardware defects and provides fast replacement solutions for defective units.

    Q10: What precautions are needed in high-humidity or coastal environments?
    A10: Coastal and high-humidity locations demand regular anti-corrosion connector maintenance, sealed patch panels and frequent end-face cleaning to avoid salt contamination and metal oxidation. Our transceivers use robust metal housings and stable internal components, while proper cable management and dust caps remain necessary to extend service life.


    Packaging & Custom OEM Solutions

     

    • ESD Protection & Fast Shipping: Every module is sealed in an ESD-safe bag and ready for same-day dispatch from stock.

    • Custom OEM & Branding: We provide logo printing, private labeling, and custom packaging to help distributors and integrators build their brand—no factory investment required.

    HYTOPTODEVICE 10Gbase-bx bidi transceiver  custom packaging


    Why Network Engineers Choose HYTOPTODEVICE


    HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.

    • Up to 70% cost savings vs OEM, transparent pricing & flexible bulk rates, supported quality returns
    • 100% real-device compatible with Cisco, Huawei,Dell,Juniper, and Arista
    • ISO 9001:2015 Shenzhen factory, full lineup: 1.25G/10G/25G/40G/100G/200G/400G/800G/1.6T transceivers
    • Ample stock, fast global DHL/FedEx shipping in 3–5 working days
    • Free pre-sales engineering support for custom EEPROM  & private label firmware
    • Real switch test videos available for pre-purchase review; inspection & shipping videos provided per order


    “Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia


    Quality Certification & Compliance

     At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.

    We adhere to rigorous standards for our SFP modules and network solutions:

    • ISO 9001: Certified quality management and production consistency.

    • CE & FCC: Fully compliant for seamless Global Market Access.

    • RoHS: Committed to environmental responsibility and hazardous material control.

    • Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.

    Certified Quality. Global Standards. Guaranteed Performance.




    Rigorous Industrial Product Testing

       hytoptodevice check device and equiptment for optical transceiver module

    100% 3rd Party Compatible
    hytoptodevice 100g qsfp28 sr4 replacement
    Partial Test Demonstration
    hytoptodevice compatible optical transceiver module for ethernet,data center


    • H3C QSFP-100G-CWDM4-SM1300 compatible 100G QSFP28 transceiver, 1300nm WDM single mode 10km module
    • 100G QSFP28  2KM optical module with DDM digital diagnostic monitoring
    • 100G QSFP28 duplex LC transceiver for H3C data center switch interconnection
    • NVIDIA(Mellanox)  MMA1L30-CM  Compatible 100G QSFP28 Transceiver | 100GBASE-CWDM4 2KM Module Bulk Wholesale | HYTOPTODEVICE

    Download