| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | GLC-BX80-UA | SFP-G54-80LD |
| 2 | Cisco | Cisco GLC-BX80-UA-I | SFP-G34-10LD |
| 3 | Brocade | E1MG-1G-BXU-80 | SFP-G34-20LD |
| 4 | Dell | SFP-GE-BX80-1490 | SFP-G35-20LD |
| 5 | Extreme | MGBIC-BX80-U | SFP-G34-40LD |
| 6 | H3C | SFP-GE-LH70-SM1490-BIDI | SFP-G35-40LD |
| 7 | HPE H3C | SFP-1G-BXU-80 | SFP-G45-1BLD |
| 8 | Huawei | SFP-GE-ZBXD1 | |
| 9 | Juniper | SFP-GE80KT14R15 | |
| 10 | MikroTik | S-4554LC80D-1490 | |
| 11 | Netgear | SFP-GE-BX80 |
| Netgear Compatible | SFP-GE-BX80 | Vendor Name | HYTOPTODEVICE |
| Form Factor | SFP | Max Data Rate | 1.25Gbps |
| Wavelength | TX1490nm/RX1550nm | Max Distance | 80km |
| Connector | Simplex LC | Transmitter Type | 1490nm DFB |
| Cable Type | SMF | Receiver Type | PIN |
| TX Power | 0~5dBm | Receiver Sensitivity | < -26.0dBm |
| Protocols | SFF-8472 MSA Compliant, IEEE 802.3ah-2004 | Operation Temperature | 0 to 70°C (32 to 158°F) |
Complementary Pairing: BiDi transceivers must be deployed in matched pairs (e.g., TX1490/RX1550 with TX1550/RX1490). Mismatched wavelengths cannot establish a link.
Fiber Choice: Use Single-Mode Fiber (SMF) only. Do NOT use MMF.
Connector Match: Simplex LC (UPC/PC polish only). Do NOT use Duplex LC or APC.
Laser Safety: Class 1 Laser. Never look directly into optical ports or fiber end-faces.
ESD Safety: Wear an anti-static wrist strap before handling the transceiver.
Cleanliness & Dust: Keep dust caps installed on all unused ports. Clean fiber connectors with an optical cleaning pen before insertion; dust causes over 80% of link failures.
Optical Attenuator Required: For short-distance testing or links (<20 km), connect a 10dB–15dB attenuator to the RX port to prevent receiver damage.
Installation & Hot-Swap: MSA compliant. Insert and remove gently without powering down the device.
High Loss / Packet Drops: Ensure fiber bend radius exceeds 30 mm, inspect optical power levels, and clean connectors.
No Link: Verify complementary BIDI wavelength pairing requirement; clean Simplex LC end-faces; check port speed configuration.
1. Supported Hardware & Firmware








Q1: Does this 80km BiDi optic adhere to well‑known Multi‑Source Agreement industry specifications? A1: Yes, this BiDi SFP module strictly complies with SFP MSA specifications. As long as the media converter has a matching 1.25G SFP slot and supports single‑mode single‑fiber connections, basic interoperability can be achieved. Custom EEPROM may still be needed to eliminate Netgear ProSAFE vendor‑specific alarm logs.
Q2: Is complementary wavelength matching mandatory to establish functional BiDi fiber connectivity? A2: Yes. BiDi technology requires complementary wavelengths. You must pair a TX1490nm/RX1550nm module at one end with a TX1550nm/RX1490nm module at the other. Using identical‑wavelength units on both sides will result in total link loss and LOS alarms.
Q3: Am I allowed to implement this long‑reach BiDi transceiver alongside multimode fiber cabling? A3: No. Long‑reach transceivers (80km) are designed exclusively for single‑mode fiber. Multimode fiber cannot satisfy the optical dispersion and loss requirements for 80km 1000BASE‑BX‑U transmission. Use only OS1 or OS2 single‑mode fiber.
Q4: Can this 80km‑rated BiDi optic be applied to fiber spans running less than 10 km? A4: Yes, but you must use an optical attenuator (e.g., 10dB–15dB) to prevent burning out the sensitive receiver optics. Excessive incoming optical power will overload the PIN receiver and trigger unstable link performance or permanent hardware damage.
Q5: Which physical fiber connector form‑factor is required for this gigabit BiDi transceiver? A5: This BiDi SFP module adopts simplex LC/UPC connector interface. Duplex LC connectors are not suitable for single‑strand BiDi operation. Make sure your patch cords are simplex‑LC terminated OS1/OS2 single‑mode fiber for correct physical mating.
Q6: Are DDM diagnostic readings functional across mixed‑brands of managed network hardware? A6: DDM/DOM follows SFF‑8472 standard, so real‑time readings of transmit power, receive power and temperature can work across most MSA‑compliant platforms. Some proprietary vendor OS including Netgear ProSAFE may hide or restrict DDM readouts for third‑party transceivers even if hardware monitoring is functional.
Q7: Can contaminated fiber connector faces trigger hardware degradation or degraded link throughput? A7: Yes. Dust, oil stains and scratches on fiber end‑faces introduce insertion loss, signal reflection and waveform distortion. It causes intermittent packet loss, link flapping, and in severe cases contaminants can transfer onto the internal transceiver optical cavity and bring permanent component degradation. Always clean LC end‑faces before installation.
Q8: Would this commercial‑grade 1.25G BiDi optic suit CPRI‑based cellular radio base‑tower deployments? A8: This is commercial‑grade (0‑70℃) BiDi SFP module, not purpose‑built for CPRI radio‑tower interfaces. It can work for gigabit Ethernet backhaul at cell‑site cabinet only if your hardware supports 1000BASE‑BX‑U and cabinet maintains commercial temperature range. For true CPRI‑compliant tower links, select dedicated CPRI optical transceivers.
Q9: What compliance paperwork should purchasers verify before confirming large‑volume wholesale orders? A9: This module meets RoHS environmental compliance, SFP MSA mechanical & electrical standards and IEEE 802.3z gigabit Ethernet specification. For wholesale procurement from manufacturer or supplier, you can request test reports covering optical parameters, aging test records and compliance documentation.
Q10: What typical MTBF rating can end‑users anticipate for this BiDi SFP under factory‑rated operating conditions? A10: Lab‑calculated typical MTBF value reaches greater than 1,000,000 hours under rated 0‑70℃ commercial operating conditions. Note MTBF is statistical theoretical index, it does not represent guaranteed service life; actual service life depends on cabinet cooling, fiber cleanliness and field operating environment.
Q11: Is custom‑tuned EEPROM programming available for obsolete or uncommon legacy network gear within bulk purchase batches? A11: Yes, custom EEPROM rewriting service is available for bulk orders. As a professional supplier & manufacturer, we can tune vendor‑specific profile for uncommon legacy switches and older hardware to clear unrecognized‑module alarms. Please supply your exact Netgear switch model, ProSAFE firmware version and original OEM part number during pre‑sales consultation.
Q12: What circumstances trigger the “Unrecognized SFP Module” alert shown on Netgear managed switch ports? A12: This alarm occurs when ProSAFE OS rejects default generic MSA EEPROM data. It is usually resolved by flashing the correct Netgear‑matched customized EEPROM profile. Confirm your device model and firmware version; some old legacy hardware also have hardware lock restrictions for third‑party optics.
Q13: Can a regular optical power meter deliver accurate validation of the module’s transmit optical power output? A13: Yes, an optical power meter calibrated for 1490‑1550 nm wavelength band can measure the transmitter output power. Keep in mind you cannot directly measure receive power from outside; receive optical value can only be read via DDM/DOM diagnostic page on the connected network switch.
Q14: What essential troubleshooting information needs submitting to technical support while handling defective transceiver issues? A14: Please provide: exact transceiver part number, host Netgear device model & ProSAFE firmware version, DDM screenshots (Tx/Rx power, temperature), fiber type & total link distance, pairing partner BiDi module wavelength, observed symptoms (LOS, flapping, alarm text), and short description of your on‑site deployment environment. This information speeds‑up fault analysis greatly.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.