| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | GLC-BX80-UA | SFP-G54-80LD |
| 2 | Cisco | Cisco GLC-BX80-UA-I | SFP-G34-10LD |
| 3 | Brocade | E1MG-1G-BXU-80 | SFP-G34-20LD |
| 4 | Dell | SFP-GE-BX80-1490 | SFP-G35-20LD |
| 5 | Extreme | MGBIC-BX80-U | SFP-G34-40LD |
| 6 | H3C | SFP-GE-LH70-SM1490-BIDI | SFP-G35-40LD |
| 7 | HPE H3C | SFP-1G-BXU-80 | SFP-G45-1BLD |
| 8 | Huawei | SFP-GE-ZBXD1 | |
| 9 | Juniper | SFP-GE80KT14R15 | |
| 10 | MikroTik | S-4554LC80D-1490 | |
| 11 | Netgear | SFP-GE-BX80 |
| Brocade Compatible | E1MG‑1G‑BXU‑80 | Vendor Name | HYTOPTODEVICE |
| Form Factor | SFP | Max Data Rate | 1.25Gbps |
| Wavelength | TX1490nm/RX1550nm | Max Distance | 80km |
| Connector | Simplex LC | Transmitter Type | 1490nm DFB |
| Cable Type | SMF | Receiver Type | PIN |
| TX Power | 0~5dBm | Receiver Sensitivity | < -26.0dBm |
| Protocols | SFF-8472 MSA Compliant, IEEE 802.3ah-2004 | Operation Temperature | 0 to 70°C (32 to 158°F) |
Complementary Pairing: BiDi transceivers must be deployed in matched pairs (e.g., TX1490/RX1550 with TX1550/RX1490). Mismatched wavelengths cannot establish a link.
Fiber Choice: Use Single-Mode Fiber (SMF) only. Do NOT use MMF.
Connector Match: Simplex LC (UPC/PC polish only). Do NOT use Duplex LC or APC.
Laser Safety: Class 1 Laser. Never look directly into optical ports or fiber end-faces.
ESD Safety: Wear an anti-static wrist strap before handling the transceiver.
Cleanliness & Dust: Keep dust caps installed on all unused ports. Clean fiber connectors with an optical cleaning pen before insertion; dust causes over 80% of link failures.
Optical Attenuator Required: For short-distance testing or links (<20 km), connect a 10dB–15dB attenuator to the RX port to prevent receiver damage.
Installation & Hot-Swap: MSA compliant. Insert and remove gently without powering down the device.
High Loss / Packet Drops: Ensure fiber bend radius exceeds 30 mm, inspect optical power levels, and clean connectors.
No Link: Verify complementary BIDI wavelength pairing requirement; clean Simplex LC end-faces; check port speed configuration.
1. Supported Hardware & Firmware
● Brocade Managed Switches
○ ICX 6430, ICX 6450, ICX 7250, ICX 7450 Series
○ FCX, FGS, FLS Series








Q1: Can this Brocade‑branded‑profile BiDi SFP work on my existing Brocade or third‑party network hardware? A1: Yes, it works with qualified Brocade IronWare devices. Pre‑flashed Brocade‑matched EEPROM enables plug‑and‑play on FastIron / NetIron platforms; custom EEPROM programming is required for Cisco, H3C, Juniper, Dell hardware. Conduct sample validation before large‑volume project procurement to prevent transceiver identification alarms.
Q2: Is it allowed to insert this 1.25G BiDi SFP into a 10G‑rate SFP+ hardware port? A2: Most 10G SFP+ ports support backward compatibility for 1.25G SFP, but you must manually force port speed to 1G on your switch configuration. Physical insertion fit cannot guarantee auto‑negotiation success, manual speed setting is mandatory to obtain stable gigabit link.
Q3: Can I mix this Tx1490/Rx1550 BiDi optic with regular dual‑fiber gigabit SFP modules to bring up link? A3: No, mixing these two module types cannot establish usable network link. This BiDi leverages WDM wavelength multiplexing over one fiber strand, whereas dual‑fiber SFP transmits on two independent fibers. Always use matched reverse‑wavelength BiDi transceiver pairs instead of mixing dual‑fiber optics.
Q4: What network failure will occur if two identical‑wavelength BiDi transceivers are fitted on both ends of fiber link? A4: You will observe no link status and LOS alarm triggered on connected network equipment. Both ends transmit at 1490nm and receive at 1550nm without wavelength cross‑match. One side needs Tx1490/Rx1550 and opposite side must adopt Tx1550/Rx1490 to finish bidirectional WDM transmission.
Q5: How can network engineers tell apart Tx1490 and Tx1550 BiDi units during on‑site installation? A5: Read the printed marking text on SFP module outer housing. Every BiDi SFP has clear Tx/Rx wavelength printed label. Do not judge only by latch color; double‑check printed wavelength information before wiring to avoid wrong‑pairing errors.
Q6: Which fiber patch‑cable specification is mandatory when deploying this Brocade compatible BiDi transceiver? A6: You have to deploy simplex LC OS1 / OS2 single‑mode fiber patch cords. Duplex‑LC and multimode fiber cable are not suitable for single‑strand BiDi 80km transmission. Clean simplex‑LC connector end‑faces before connection to cut insertion loss and reduce intermittent LOS risks for long‑distance links.
Q7: What optical chip combination is adopted on this 80km Brocade compatible BiDi SFP? A7: This BiDi SFP equips DFB laser transmitter together with PIN receiver. PIN receiver achieves receiving sensitivity down to ‑26 dBm. This mature chip combination keeps stable optical performance for 80km long‑haul single‑mode fiber transmission.
Q8: What link‑budget performance can I expect for this 80km BiDi transceiver in real‑world enterprise deployment? A8: Our module delivers TX output 0‑5 dBm and RX sensitivity better than ‑26 dBm, providing minimum 26 dB link budget. Typical single‑mode fiber attenuation reaches approx 0.25 dB/km within 1490‑1550nm window. Reserve loss margin for field‑site splices and connector joints; keep overall loss within 26 dB to guarantee full‑distance stable running.
Q9: Does this long‑reach 80km BiDi SFP consume noticeably more power than short‑range 10km‑20km BiDi optics? A9: No, power consumption remains well‑controlled below 1W. This unit uses DFB laser and PIN receiver chipset. It fully complies with SFP MSA power specification and will not overload standard SFP host ports.
Q10: For enterprise projects, what practical advantages does single‑fiber BiDi SFP bring compared with traditional dual‑fiber optical modules? A10: BiDi SFP halves fiber‑core occupancy for sites suffering fiber shortage. It uses WDM technique for bidirectional signal transmission over only one fiber strand. It fits campus inter‑building links, remote branch backhaul and network renovation where laying extra fiber pairs brings high construction cost.
Q11: Is this BiDi transceiver suitable to integrate inside existing CWDM or DWDM multiplexing network infrastructure? A11: It is not suggested to use this module in standard CWDM / DWDM systems. Its fixed 1490/1550nm wavelengths overlap common CWDM channel spectrum. Choose CWDM‑specific qualified optical transceivers if wavelength‑multiplexing networking is required for your enterprise project.
Q12: What warranty terms apply when purchasing this Brocade‑compatible BiDi SFP for bulk project orders? A12: HYTOPTODEVICE provides standard 5‑year factory warranty for manufacturing defects. Warranty applies to hardware failure occurring under rated 0‑70℃ operating conditions; damage caused by ESD shock, contaminated fiber end‑faces, optical overload and improper field‑site handling falls outside warranty coverage.
Q13: Why is an 80km BiDi SFP more costly compared with shorter‑reach 10km /20km BiDi transceiver options? A13: High‑power DFB/EML lasers, high‑sensitivity PIN receivers, and tight wavelength isolation filters drive up manufacturing costs. Short‑reach BiDi modules can adopt lower‑grade optical components. Additional precise calibration and burn‑in testing for long‑haul performance further increase production expense.
Q14: Troubleshooting steps: How should network technicians resolve Rx Power Low or LOS alarms triggered on Brocade switches? A14: Start troubleshooting from physical‑layer connections. Clean simplex‑LC patch‑cord end‑faces, reseat SFP transceivers, double‑check BiDi wavelength pairing status and test total link optical loss. If measured loss exceeds module power budget, shorten transmission distance or deploy fiber amplifier for long‑haul single‑fiber links.
Q15: What root reasons cause unstable intermittent link flapping on BiDi single‑fiber enterprise links? A15: Link flapping mostly originates from physical‑layer faults associated with the PIN receiver. Common causes include polluted fiber end‑faces, insufficient receiving optical margin, reversed wavelength pairing, ESD‑damaged PIN receiver or abnormal cabinet operating temperature. Check DDM real‑time optical power and temperature reading to quickly pinpoint fault sources.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.