HYTOPTODEVICE is a professional BIDI TRANSCEIVER manufacturer & supplier. This Brocade E1MG-1G-BXU-120 compatible BiDi transceiver complies with IEEE 802.3ah 1000BASE-BX-U standard. It delivers 1.25Gbps bidirectional data transmission up to 120km over OS1/OS2 single-mode fiber via simplex LC connector at Tx1490nm/Rx1550nm. Preloaded Brocade optimized EEPROM enables plug-and-play installation. We supply bulk wholesale BIDI TRANSCEIVER and provide custom EEPROM programming, OEM and private label services for global network distributors and system integrators.
-
Complementary Pairing: BiDi transceivers must be deployed in matched pairs (e.g., TX1490/RX1550 with TX1550/RX1490). Mismatched wavelengths cannot establish a link.
-
Fiber Choice: Use Single-Mode Fiber (SMF) only. Do NOT use MMF.
-
Connector Match: Simplex LC (UPC/PC polish only). Do NOT use Duplex LC or APC.
-
Laser Safety: Class 1 Laser. Never look directly into optical ports or fiber end-faces.
-
ESD Safety: Wear an anti-static wrist strap before handling the transceiver.
-
Cleanliness & Dust: Keep dust caps installed on all unused ports. Clean fiber connectors with an optical cleaning pen before insertion; dust causes over 80% of link failures.
-
Optical Attenuator Required: For short-distance testing or links (<30 km), connect a 10dB–15dB attenuator to the RX port to prevent receiver damage.
-
Installation & Hot-Swap: MSA compliant. Insert and remove gently without powering down the device.
-
High Loss / Packet Drops: Ensure fiber bend radius exceeds 30 mm, inspect optical power levels, and clean connectors.
-
No Link: Verify complementary BIDI wavelength pairing requirement; clean Simplex LC end-faces; check port speed configuration.
Primary Application Scenarios
● Single-fiber point-to-point inter-switch links for metro enterprise networks
● Cross-town gigabit interconnection with limited available fiber pairs
● Remote branch office long-haul backhaul over leased dark fiber lines
● Extra-long-distance uplink for distributed IP camera monitoring systems
● Metro network upgrade projects with constrained fiber infrastructure
Connectivity Solutions (Applications)
1.1GbE Switch-to-Switch Connectivity
2.1GbE Switch to Media Converter Connectivity
3.1G Structured Cabling
Core Product Features
1. BiDi SFP: Maximizing Fiber Efficiency
Replaces traditional dual-fiber setups with single-strand WDM multiplexing, fully unlocking unused fiber capacity and streamlining bulk network upgrades.

2.Double Your Capacity, Zero Extra Cabling
Transmit and receive on a single strand. By leveraging integrated WDM technology, this BiDi transceiver eliminates redundant wiring and slashes expansion costs for campus networks.

3. Efficient 1G Ethernet, Half the Fiber
Maximize data center efficiency. Delivers reliable Gigabit performance while lowering power consumption and halving fiber strand requirements.

4. Plug-and-Play Guaranteed Compatibility
Factory programmed Brocade-matched EEPROM suppresses third-party module warning logs. Hot swap works directly on supported switches and routers without complex CLI setup; custom EEPROM can be arranged upon bulk request. Specific Compatibility Video available upon request.

5. 100% Tested, Zero-Defect Guaranteed
Maximum network uptime, zero surprises. Every BIDI Transceiver undergoes rigorous physical testing in our Test Center before shipping to deliver rock-solid reliability out of the box.

Frequently Asked Questions
Q1: Will this 1.25G 120km single fiber BiDi optic run properly on Brocade, Cisco or MikroTik gigabit switching hardware?
A: Yes, this HYTOPTODEVICE BIDI TRANSCEIVER works for these switch platforms with standard gigabit SFP slots. Pre-calibrated EEPROM ensures drop-in interoperability for compatible 1.25G SFP ports.
Q2: Can I slot this BiDi transceiver into a 10G SFP+ port on my network switch?
A: Yes, most SFP+ ports support backward compatibility for 1.25G SFP transceivers. You need manually set port speed to 1G on the switch; auto-negotiation may fail without manual port configuration.
Q3: Does my network switch require firmware upgrades to identify this BiDi optical transceiver?
A: No extra firmware upgrade is required for most supported switches. HYTOPTODEVICE custom EEPROM handles module identification; only confirm your existing firmware supports standard MSA SFP hardware.
Q4: How should I resolve "unsupported transceiver" alert after inserting this BiDi module?
A: This warning can be cleared via switch CLI configuration or pre-customized EEPROM from HYTOPTODEVICE. The alert is merely vendor ID verification, and the optic itself still transmits stable 1.25G optical signals.
Q5: Is it feasible to pair this 120km BiDi transceiver with a 40km or 80km BiDi optic at the opposite fiber end?
A: Yes, provided the TX/RX wavelengths match and you use an inline optical attenuator to prevent overloading the shorter-reach receiver. Mismatched power budget remains the main risk even with correct wavelength pairing.
Q6: What is the quick method to distinguish TX1490 and TX1550 BiDi modules during field installation?
A: You can quickly identify them from printed markings on the module housing. HYTOPTODEVICE clearly prints Tx/Rx wavelength specs on the module label to avoid reversed pairing during site deployment.
Q7: Will bench testing this 120km BiDi module with short fiber patch cords damage the internal receiver?
A: Yes, high transmit power will risk permanent damage to the APD receiver on short fiber links. Fit a 10~15dB inline optical attenuator to reduce incoming optical power during bench lab testing.
Q8: Are inline optical attenuators mandatory when deploying this BiDi transceiver in field fiber installations?
A: Attenuators are required for all fiber spans shorter than 30km. Use a 10–15dB inline attenuator for these short runs; links longer than 30km have sufficient natural fiber loss and no attenuator is needed for this HYTOPTODEVICE 120km BiDi transceiver.
Q9: Can this 120km BiDi transceiver operate over multimode fiber (MMF) cable?
A: No, this 120km BiDi transceiver only supports OS1/OS2 single-mode fiber. MMF has high optical attenuation at 1490/1550nm and cannot sustain long-distance gigabit transmission.
Q10: What optical performance metrics can be monitored in real time through the DDM function?
A: DDM continuously tracks critical optical performance metrics. You can read transmit power, receive power, module temperature and supply voltage through switch CLI or web UI on this HYTOPTODEVICE BIDI TRANSCEIVER.
Q11: Can DDM monitoring send early warnings before the long-distance fiber link completely drops offline?
A: Yes, DDM has pre-configured pre-failure alarm thresholds for optical power. It alerts network engineers before total link loss, helping avoid unexpected outages on metro long haul fiber links.
Q12: Can I deploy this BiDi transceiver inside unconditioned outdoor network cabinets?
A: This commercial grade HYTOPTODEVICE BIDI TRANSCEIVER supports operating temperature of 0°C ~ +70°C and cannot withstand extreme outdoor temperature. Choose HYTOPTODEVICE industrial version (-40°C ~ +85°C) if deployed inside unconditioned outdoor cabinets.
Q13: What is the maximum power draw of this SFP BiDi optical module?
A: Max power consumption of this SFP transceiver is ≤1W. Its low-power DFB laser plus APD receiver design keeps heat low for dense SFP slot deployment inside enterprise switch racks.
Q14: Why is the 120km BiDi transceiver more costly than 10km or 40km BiDi optical modules?
A: Higher-grade optical components increase manufacturing cost. It adopts high-performance DFB laser, high-sensitivity APD receiver and precise wavelength filters required for reliable 120km single-fiber transmission.
Q15: What technical assistance can HYTOPTODEVICE offer when long haul fiber links fluctuate or fail to establish?
A: HYTOPTODEVICE provides professional pre-sales and after-sales technical support for bulk wholesale BIDI TRANSCEIVER orders. Our engineering team assists troubleshooting and offers field testing guidance for BiDi transceiver deployments.
Packaging & Custom OEM Solutions
Individually sealed in ESD-safe packaging and ready to ship. We offer tailored OEM solutions—including custom logos and private labeling—to support high-volume distributors,wholesaler and system integrators.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
- 100% hardware-tested compatibility with Cisco, Huawei,Dell,Juniper, and Arista
- ISO 9001:2015 certified manufacturing facility in Shenzhen
- Full product range coverage:1.25G/10G/25G/40G/100G/200G/400G/800G/1.6T
- In-stock supply & fast global shipping, average lead time of 3–5 business days with DHL/FedEx express options
- Dedicated pre-sales engineering support for custom configurations
- Actual hardware,actual switches,actual results.we publish compatibility test video,eliminate compatibility anxiety. you can watch before you buy.
- We can provide inspection and shipping videos to make you feel as if you are right here with the product.
- Private Label support - EEPROM / firmware customization support
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
-
ISO 9001: Certified quality management and production consistency.
-
CE & FCC: Fully compliant for seamless Global Market Access.
-
RoHS: Committed to environmental responsibility and hazardous material control.
-
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.

Rigorous Industrial Product Testing

100% 3rd Party Compatible

Partial Test Demonstration