| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | GLC-BX80-DA | SFP-G45-80LD |
| 2 | Cisco | Cisco GLC-BX80-DA-I | SFP-G43-10LD |
| 3 | Brocade | E1MG-1G-BXD-80 | SFP-G43-20LD |
| 4 | Dell | SFP-GE-BX80-1550 | SFP-G53-10LD |
| 5 | Extreme | MGBIC-BX80-D | SFP-G53-20LD |
| 6 | H3C | SFP-GE-LH70-SM1550-BIDI | SFP-G43-40LD |
| 7 | HPE H3C | SFP-1G-BXD-80 | SFP-G53-40LD |
| 8 | Huawei | SFP-GE-ZBXD1 | SFP-G54-1BLD |
| 9 | Juniper | SFP-GE80KT15R14 | |
| 10 | MikroTik | S-4554LC80D-1550 | |
| 11 | Netgear | SFP-GE-BX80-D |
| Cisco Compatible | GLC-BX80-DA-I | Vendor Name | HYTOPTODEVICE |
| Form Factor | SFP | Max Data Rate | 1.25Gbps |
| Wavelength | TX1550nm/RX1490nm | Max Distance | 80km |
| Connector | Simplex LC | Transmitter Type | 1550nm DFB |
| Cable Type | SMF | Receiver Type | PIN |
| TX Power | 0~5dBm | Receiver Sensitivity | < -26.0dBm |
| Protocols | SFF-8472 MSA Compliant, IEEE 802.3ah-2004 | Operation Temperature | -40 to 85°C (-40 to 185°F) |
Complementary Pairing: BiDi transceivers must be deployed in matched pairs (e.g., TX1490/RX1550 with TX1550/RX1490). Mismatched wavelengths cannot establish a link.
Fiber Choice: Use Single-Mode Fiber (SMF) only. Do NOT use MMF.
Connector Match: Simplex LC (UPC/PC polish only). Do NOT use Duplex LC or APC.
Laser Safety: Class 1 Laser. Never look directly into optical ports or fiber end-faces.
ESD Safety: Wear an anti-static wrist strap before handling the transceiver.
Cleanliness & Dust: Keep dust caps installed on all unused ports. Clean fiber connectors with an optical cleaning pen before insertion; dust causes over 80% of link failures.
Optical Attenuator Required: For short-distance testing or links (<20 km), connect a 10dB–15dB attenuator to the RX port to prevent receiver damage.
Installation & Hot-Swap: MSA compliant. Insert and remove gently without powering down the device.
High Loss / Packet Drops: Ensure fiber bend radius exceeds 30 mm, inspect optical power levels, and clean connectors.
No Link: Verify complementary BIDI wavelength pairing requirement; clean Simplex LC end-faces; check port speed configuration.
1. Supported Hardware & Firmware








Q1: Does this industrial 80km SFP BIDI transceiver follow SFP MSA mechanical and electrical standards? A1: Yes, this industrial SFP BIDI transceiver fully complies with SFP MSA specs. Any hardware with standard 1.25G SFP slots and single-fiber support can achieve basic interoperability. Custom EEPROM may still be required to remove Cisco IOS vendor-specific alarm logs.
Q2: Is wavelength pairing mandatory to set up a working BiDi single fiber gigabit link? A2: Yes. BiDi communication requires matched opposite wavelength pairs. Pair this Tx1550/Rx1490 module with Tx1490/Rx1550 BiDi transceiver on the opposite end. Using same wavelength modules on both sides creates total link loss and LOS alarms.
Q3: Can I deploy this industrial long-range BiDi transceiver using multimode fiber cables? A3: No. This 80km transceiver is designed exclusively for single-mode fiber. Multimode fiber cannot satisfy dispersion and loss requirements for 80km 1000BASE-BX-D transmission, only use OS1 or OS2 single-mode fiber.
Q4: Can this 80km-rated industrial SFP BIDI transceiver be used on fiber spans shorter than 10km? A4: Yes, but you must install inline optical attenuator (10–15dB) to protect the sensitive PIN receiver. Excessive received optical power overloads receiver and causes unstable links or permanent hardware damage.
Q5: What fiber connector type is required for this industrial gigabit BiDi optical transceiver? A5: This SFP BIDI transceiver uses simplex LC/UPC connector. Duplex LC connectors are not compatible for single-strand BiDi operation. Use simplex-LC terminated OS1/OS2 single-mode patch cords for proper connection.
Q6: Will DDM DOM optical monitoring function properly across mixed brands of industrial switches and routers? A6: DDM/DOM follows SFF-8472 standard, supporting real-time Tx power, Rx power and temperature readings on most MSA-compliant hardware. Cisco IOS may limit or hide DDM readouts for third-party transceivers even if hardware monitoring works.
Q7: Can unclean fiber connector end faces trigger transceiver failure or intermittent industrial network link drops? A7: Yes. Dust, oil and scratches on fiber ends introduce insertion loss and signal reflection. It causes intermittent packet loss and link flapping; heavy contamination can damage internal optical parts. Always clean LC connectors before field installation.
Q8: Can this wide-temperature industrial SFP BIDI transceiver be applied to CPRI cellular tower radio interfaces? A8: This industrial grade (-40~85°C) SFP BIDI transceiver supports gigabit Ethernet only, it is not built for CPRI radio interfaces. It works for gigabit backhaul if your hardware supports 1000BASE-BX-D. Choose dedicated CPRI optics for tower CPRI links.
Q9: What compliance documents should buyers request when placing bulk wholesale orders of industrial BiDi transceivers? A9: This transceiver meets RoHS, SFP MSA and IEEE 802.3z gigabit Ethernet standard. When purchasing bulk from manufacturer, you can request optical test reports, thermal aging burn-in records and compliance certificates.
Q10: What MTBF value can buyers expect for this industrial SFP BIDI transceiver under rated wide temperature working conditions? A10: Lab tested typical MTBF exceeds 1,000,000 hours within -40~85°C industrial temperature range. MTBF is a statistical value and not a guaranteed service life; actual lifespan depends on cabinet cooling, fiber cleanliness and harsh site environment.
Q11: Is custom EEPROM programming available for older legacy Cisco IE industrial switches during bulk procurement? A11: Yes, custom EEPROM rewriting service is available for bulk orders. As a transceiver manufacturer, we can customize vendor profiles for legacy Cisco industrial hardware to clear unrecognized module alerts. Please provide exact Cisco model, IOS firmware version and OEM part number in pre-sales consultation.
Q12: What causes the “Unsupported Transceiver” warning on Cisco IE industrial switch SFP ports? A12: This alert appears when Cisco IOS rejects generic default EEPROM data. It is normally fixed by flashing Cisco-matched customized EEPROM profile. Verify device model and firmware; some older Cisco industrial hardware has hardware locks for third-party optics.
Q13: Can a standard optical power meter validate the transmit optical power of this industrial BiDi transceiver? A13: Yes, an optical power meter calibrated for 1550–1490nm wavelength band can measure transmit power. Receive power cannot be measured externally; read Rx power via DDM/DOM page on the connected Cisco network device.
Q14: What troubleshooting information should I submit to technical support when facing faulty industrial transceiver issues? A14: Prepare these details: transceiver part number, Cisco IE host device model & IOS firmware version, DDM screenshots (Tx/Rx power, temperature), fiber type & total link distance, paired BiDi module wavelength, symptoms (LOS, link flapping, alarm text) and field site environment description. This information speeds fault diagnosis greatly.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.



