| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | GLC-BX80-DA | SFP-G45-80LD |
| 2 | Cisco | Cisco GLC-BX80-DA-I | SFP-G43-10LD |
| 3 | Brocade | E1MG-1G-BXD-80 | SFP-G43-20LD |
| 4 | Dell | SFP-GE-BX80-1550 | SFP-G53-10LD |
| 5 | Extreme | MGBIC-BX80-D | SFP-G53-20LD |
| 6 | H3C | SFP-GE-LH70-SM1550-BIDI | SFP-G43-40LD |
| 7 | HPE H3C | SFP-1G-BXD-80 | SFP-G53-40LD |
| 8 | Huawei | SFP-GE-ZBXD1 | SFP-G54-1BLD |
| 9 | Juniper | SFP-GE80KT15R14 | |
| 10 | MikroTik | S-4554LC80D-1550 | |
| 11 | Netgear | SFP-GE-BX80-D |
| Brocade Compatible | E1MG-1G-BXD-80 | Vendor Name | HYTOPTODEVICE |
| Form Factor | SFP | Max Data Rate | 1.25Gbps |
| Wavelength | TX1550nm/RX1490nm | Max Distance | 80km |
| Connector | Simplex LC | Transmitter Type | 1550nm DFB |
| Cable Type | SMF | Receiver Type | PIN |
| TX Power | 0~5dBm | Receiver Sensitivity | < -26.0dBm |
| Protocols | SFF-8472 MSA Compliant, IEEE 802.3ah-2004 | Operation Temperature | 0 to 70°C (32 to 158°F) |
Complementary Pairing: BiDi transceivers must be deployed in matched pairs (e.g., TX1550/RX1490 with TX1490/RX1550). Mismatched wavelengths cannot establish a link.
Fiber Choice: Use Single-Mode Fiber (SMF) only. Do NOT use MMF.
Connector Match: Simplex LC (UPC/PC polish only). Do NOT use Duplex LC or APC.
Laser Safety: Class 1 Laser. Never look directly into optical ports or fiber end-faces.
ESD Safety: Wear an anti-static wrist strap before handling the transceiver.
Cleanliness & Dust: Keep dust caps installed on all unused ports. Clean fiber connectors with an optical cleaning pen before insertion; dust causes over 80% of link failures.
Optical Attenuator Required: For short-distance testing or links (<20 km), connect a 10dB–15dB attenuator to the RX port to prevent receiver damage.
Installation & Hot-Swap: MSA compliant. Insert and remove gently without powering down the device.
High Loss / Packet Drops: Ensure fiber bend radius exceeds 30 mm, inspect optical power levels, and clean connectors.
No Link: Verify complementary BIDI wavelength pairing requirement; clean Simplex LC end-faces; check port speed configuration.
1. Supported Hardware & Firmware
● Brocade Managed Switches
○ ICX 6430, ICX 6450, ICX 7250, ICX 7450 Series
○ FCX, FGS, FLS Series








Q1: Does this 80km SFP BiDi transceiver conform to SFP MSA mechanical and electrical industry standards? A1: Yes, this SFP BiDi transceiver fully meets SFP MSA specifications. Any device with standard 1.25G SFP slots and single-fiber support can achieve basic interoperability. Custom EEPROM may still be needed to clear Brocade vendor-specific alarm messages.
Q2: Do I need matched complementary wavelength BiDi pairs to build a working single fiber gigabit link? A2: Yes. BiDi transmission relies on opposite wavelength pairing. Pair this Tx1550/Rx1490 transceiver with Tx1490/Rx1550 BiDi module at the far end. Same wavelength modules on both sides will result in complete link loss and LOS alarms.
Q3: Can multimode fiber cables be used with this long-distance BiDi transceiver? A3: No. This 80km transceiver is designed exclusively for single-mode fiber. Multimode fiber cannot meet dispersion and loss requirements for 1000BASE-BX-D 80km transmission, only OS1 or OS2 single-mode fiber is suitable.
Q4: Can this 80km-rated SFP BiDi transceiver operate on fiber links shorter than 10km? A4: Yes, but you must add inline optical attenuator (10–15dB) to protect the sensitive PIN receiver. Excessive received optical power overloads the receiver and causes unstable links or permanent hardware damage.
Q5: What type of fiber connector does this gigabit BiDi optical transceiver require? A5: This SFP BiDi transceiver uses simplex LC/UPC connector. Duplex LC connectors are not compatible with single-strand BiDi operation. Use simplex-LC terminated OS1/OS2 single-mode patch cords for correct connection.
Q6: Will DDM DOM optical monitoring work properly across different brands of managed switches? A6: DDM/DOM follows SFF-8472 standard, supporting real-time Tx power, Rx power and temperature readings on most MSA-compliant hardware. Brocade firmware may limit DDM readouts for third-party transceivers even when hardware monitoring functions.
Q7: Will dirty fiber connector ends lead to transceiver damage or intermittent network link drops? A7: Yes. Dust, grease and scratches on fiber ends introduce insertion loss and signal reflection. This triggers random packet loss and link flapping; heavy contamination may damage internal optical components. Always clean LC connectors before installation.
Q8: Is this commercial grade 1.25G BiDi transceiver suitable for CPRI radio tower site connections? A8: This commercial (0-70°C) SFP BiDi transceiver supports gigabit Ethernet only and is not designed for CPRI radio interfaces. It works for gigabit backhaul only if your hardware supports 1000BASE-BX-D. Select dedicated CPRI optics for tower CPRI links.
Q9: What compliance documents should buyers request before confirming bulk factory wholesale orders? A9: This transceiver complies with RoHS, SFP MSA mechanical/electrical rules and IEEE 802.3z gigabit Ethernet standard. When ordering bulk directly from factory, you can request optical test reports, burn-in records and compliance certificates.
Q10: What MTBF performance can customers expect for this SFP BiDi transceiver under rated working temperature? A10: Lab tested typical MTBF exceeds 1,000,000 hours at 0–70°C commercial temperature. MTBF is a statistical value and not a guaranteed service life; actual service life depends on cabinet cooling, fiber cleanliness and field environment.
Q11: Is custom EEPROM programming available for older legacy Brocade switches during bulk procurement? A11: Yes, custom EEPROM rewriting service is available for bulk orders. As a transceiver manufacturer, we can customize vendor profiles for legacy Brocade hardware to resolve unrecognized module alerts. Please provide exact Brocade switch model, firmware version and OEM part number in pre-sales consultation.
Q12: What triggers the “Unsupported Transceiver” warning message on Brocade switch SFP ports? A12: This warning appears when Brocade firmware rejects generic default EEPROM data. It can usually be fixed by flashing Brocade-matched customized EEPROM profile. Confirm device model and firmware; some older Brocade hardware includes locks for third-party optics.
Q13: Can a regular optical power meter verify the transmit optical power output of this BiDi transceiver? A13: Yes, an optical power meter calibrated for 1550–1490nm wavelength band can measure transmit power. Receive power cannot be measured externally; read Rx power through DDM/DOM page on the connected Brocade network device.
Q14: What troubleshooting details should be sent to technical support when handling defective transceiver issues? A14: Prepare these details: transceiver part number, Brocade host device model & firmware version, DDM screenshots (Tx/Rx power, temperature), fiber type & total link distance, paired BiDi module wavelength, symptoms (LOS, link flapping, alarm text) and site deployment description. This information speeds fault diagnosis greatly.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.