• 
Extreme compatible 10GB-BX60-D module from hytoptodevice
  • 
10GB-BX60-D sfp+ bidi 60km transceiver
  • 1330nm TX 1270nm RX SFP 10G BiDi Transceiver 60km internal structure shot
  • Bulk wholesale SFP 10G BiDi Transceiver 60km for Extreme Networks switches from hytoptodevice
  • DDM-supported paired SFP 10G BiDi Transceiver 60km high-precision detail display
  • 
Extreme compatible 10GB-BX60-D module from hytoptodevice
  • 
10GB-BX60-D sfp+ bidi 60km transceiver
  • 1330nm TX 1270nm RX SFP 10G BiDi Transceiver 60km internal structure shot
  • Bulk wholesale SFP 10G BiDi Transceiver 60km for Extreme Networks switches from hytoptodevice
  • DDM-supported paired SFP 10G BiDi Transceiver 60km high-precision detail display

Extreme 10GB-BX60-D Compatible SFP 10G BiDi Transceiver | 10GBASE-BX60-D 60km Tx1330Rx1270nm Bulk Wholesale | HYTOPTODEVICE

Shop Extreme 10GB-BX60-D compatible SFP 10G BiDi Transceiver, 60km 1330nm-TX/1270nm-RX single-strand simplex LC SMF, Compliant with SFP+ MSA, SFF-8472, IEEE 802.3ae. 100% real-hardware tested, plug-and-play on all Extreme devices with full DDM monitoring. ideal for campus cross-building links, available for enterprise bulk procurement. support private labeling and OEM customization, long-term supply for global importers, integrators and distributors.
NO. Brand  Compatible P/N Transceiver Type
1 Juniper EX-SFP-10GE-BX32-60 SFP-10G23-BX60
2 Brocade 10G-SFPP-BXD-60K  SFP-10G32-BX20
3 Dell GP-SFP-10GBX-D-60 SFP-10G32-BX40
4 Ciena XCVR-S60U33 SFP-10G54-BX80
5 Extreme 10GB-BX60-D SFP-10G54-BX100


Description

HYTOPTODEVICE Extreme 10GB-BX60-D Compatible  SFP 10G SFP Transceiver – Simplex LC Single-Fiber BiDi 10G 60km Single-Mode Optic, Native Ciena OS Recognition, Bulk Wholesale Procurement Available


Product Overview

HYTOPTODEVICE SFP 10G BiDi Transceiver 60km acts as a fully validated drop-in replacement for original Extreme 10GB-BX60-D, designed for stable 60km single fiber long-distance metro transmission. Equipped with standard 1330nm TX / 1270nm RX BiDi wavelength matching and simplex LC connector, this custom-programmed BiDi optic delivers steady 10.3125Gbps full-duplex bandwidth over standard single-mode fiber. Fully verified for native compatibility with Extreme operating firmware and complete DDM real-time diagnostic monitoring, this SFP 10G BiDi Transceiver 60km perfectly fits metro backbone interconnection, cross-campus WAN extension and dark fiber resource activation projects. We provide bulk wholesale solutions and complimentary custom EEPROM reflash services, helping global system integrators and telecom operators cut Exgreme  long-haul fiber deployment costs with zero compatibility risks.

Key Technical Specifications
Extreme  Compatible  10GB-BX60-D Vendor Name HYTOPTODEVICE
Form Factor SFP+ Max Data Rate 10.7Gbps
Wavelength TX1330nm/RX1270nm Max  Distance 60km
Connector Simplex LC Transmitter Type 1330nm DFB
Cable Type SMF Receiver Type APD
TX Power 1.0~+6dBm Receiver Sensitivity < -20dBm
Max. Power Consumption ≤1.4W DOM/DDM   Fully Supported
Protocols SFP+ MSA, SFF-8472, IEEE 802.3ae, RoHS Compliant Operation Temperature 0 to 70°C (32 to 158°F)

For detailed technical specifications, please refer to the Datasheet

 
Usage Guidelines & Operational Best Practices

• BiDi Pairing Rule: SFP‑10G‑BXD (Tx1330/Rx1270) must pair with SFP‑10G‑BXU (Tx1270/Rx1330) at remote end. Two BXD modules will NOT form a valid link.
• Cabling Requirement: Use OS2 single‑mode simplex‑LC UPC cables only. Multimode fiber / APC connectors reduce reach and cause link issues; keep connectors clean.
• Optical Attenuator Required for Short Links: For testing or short‑distance connections (<10km), connect a 12dB–15dB optical attenuator to the RX port to prevent damaging the receiver.(10KM<Distance<30km,connect 5‑15dB optical attenuator)
• Environment: Run within 0‑70 °C. Avoid high‑heat, dusty, poorly ventilated rack positions.
• Hot‑swap: Supports hot‑swap; disconnect fiber before plugging / unplugging to protect optical ports.
• DDM Monitoring: Enable DDM/DOM; monitor optical power and temperature for early fault warning.
• Pre‑test Recommendation: Test sample units with real hardware before large‑scale bulk deployment.
• Laser Safety: Avoid direct eye exposure to powered optical ports; infrared laser can harm eyes.

For detailed operation instructions, please refer to the User Guide.


Full Compatibility List & Supported Network Hardware

1.Native Extreme Networks Compatibility
HYTOPTODEVICE custom coded SFP 10G BiDi Transceiver 60km achieves 100% plug-and-play compatibility with  Extreme 10GB-BX60-D and all mainstream Extreme switching firmware versions. Every production batch completes real physical Extreme switch online testing, supporting accurate port identification, complete DDM data display, and zero port startup failure or firmware upgrade conflict. We can provide professional test reports and real-machine debugging videos to eliminate hidden third-party module compatibility risks for Extreme long-haul single-fiber telecom networks.

  • Compatible Series: Extreme Ethernet & Service Delivery Switches
  • Compatible Model: Direct drop-in replacement for  Extreme 10GB-BX60-D
  • System Support: All official Extreme firmware versions with no upgrade incompatibility

2.Multi-Brand Cross Compatibility
Built to universal SFP MSA standards, HYTOPTODEVICE SFP 10G BiDi Transceiver 60km breaks OEM vendor lock-in to support hybrid multi-vendor telecom and enterprise metro networks.

  • Open-Brand (Plug-and-Play): Fortinet, Ubiquiti, MikroTik, D-Link, Zyxel and other open switches
  • Locked-Brand (Custom Coding): Cisco, H3C, Huawei, Dell, Juniper and more

3.Free Custom EEPROM Re-Flash Service
Complimentary permanent EEPROM rewrite service for all bulk orders of SFP 10G BiDi Transceiver 60km. Whether upgrading Extreme firmware or migrating existing modules to multi-brand network racks, our professional engineering team re-programs module firmware free of charge to adapt to diverse device authentication mechanisms, ensuring stable 60km single-fiber bidirectional link operation for evolving multi-vendor metro and telecom network architectures.


Primary Application Scenarios

HYTOPTODEVICE SFP 10G BiDi Transceiver 60km is specially optimized for Extreme network architecture, widely used in high-value long-haul transmission scenarios:

- 60km Metro Backbone Interconnection: Solve bandwidth bottlenecks of urban and suburban Extreme single-fiber backbone transmission with limited fiber resources.
- Cross-Campus & Cross-Building WAN Extension: Realize low-cost long-distance network interconnection of enterprise parks, campuses and remote branch offices.
- Legacy Fiber Network Renovation & Dark Fiber Activation: Make full use of idle single fiber cores to complete 10G high-speed network upgrade without repeated cabling investment.
- Outdoor Long-Distance Pipeline & Aerial Transmission: Adapt to complex outdoor environments, stable operation of Extreme long-span communication links.
- Remote Monitoring & Private Line Backhaul: Provide reliable 10G long-distance data backhaul for enterprise private lines and industrial monitoring systems.

Connectivity Solutions(Applications)

1.Switch-to-Switch
extreme switch to Extreme switch single-fiber 60km BiDi 10G SFP module interconnection topology diagram

2.Switch-to-NIC
hytoptodevice Switch to server NIC long-distance single-fiber BiDi 10G SFP module 60km networking schematic drawing

3.
Core to Access (With Structured Cabling)
hytoptodevice Enterprise structured single-fiber cabling layout using Extreme compatible SFP 10G BiDi module  60km

The Core Features 

1.50% Fiber Resource Saving & Low-Cost Network Upgrade
Optimize your current network infrastructure without the high cost of laying new cables. By transmitting and receiving signals over a single strand of fiber, our 10G BiDi SFP+ transceivers help you squeeze maximum value out of your existing fiber cabling.

hytoptodevice Dual fiber 10G network upgrade to single fiber BiDi 10G SFP Transceiver 60km fiber resource optimization comparison chart

2.Double Your Network Capacity Instantly
Upgrade your bandwidth effortlessly. Utilizing advanced Wavelength Division Multiplexing (WDM) technology, this module allows bidirectional traffic over a single fiber strand, effectively doubling your network capacity instantly while cutting cabling costs in half.



3.Energy-Efficient 10G Connectivity for Data Centers
Designed for high-density, high-speed modern data centers, this SFP+ transceiver features an ultra-low power consumption of just 1W. Achieve stable, green, and cost-effective 10G data transmission while significantly reducing operational cooling costs.



4.Seamless Cross-Brand Interoperability
Enjoy worry-free integration into your multi-vendor environment. Every single unit undergoes rigorous compatibility testing on original brand switches to ensure seamless cross-brand interoperability. Real products, real switches, real results—Specific Compatibility Video available upon request.



5.Comprehensive Testing for Rock-Solid Reliability
Reliability is our cornerstone. From signal integrity and distance runs to extreme temperature cycles, our comprehensive testing procedure guarantees that every 10G BiDi 10km SFP+ module delivers stable, packet-loss-free performance under any network load before leaving our Test Center. 




FAQ

Q1: What network migration failures occur when mixing SFP 10G BiDi Transceiver 60km with legacy dual-fiber Extreme network infrastructure?

A1: Traditional legacy Extreme network architectures adopt dual-fiber transceiving design, utilizing independent fiber cores for signal transmission and reception separately. In contrast, SFP 10G BiDi Transceiver 60km integrates two-way 10G data transmission on a single fiber strand. Improperly deploying BiDi modules during network upgrades will result in failed link negotiation. This mismatched deployment mode also disrupts on-site cabling plans, triggers patching logic confusion, and delays the overall progress of Extreme enterprise network renovation and migration projects.

Q2: Why fixed-wavelength 60km BiDi modules cannot adapt to CWDM/DWDM multi-channel multiplexed Extreme networking systems?

A2: Extreme-compatibleSFP 10G BiDi Transceiver 60km is built with fixed 1270nm/1330nm internal wavelength structures without tunable frequency adjustment functions or standard WDM grid parameters. Unlike professional CWDM/DWDM dedicated modules that support multi-channel signal multiplexing, its locked wavelength design cannot match the precise channel spacing requirements of dense wavelength division multiplexing systems, making it impossible to integrate into multi-service composite WDM transmission networks for Extreme long-haul business deployment.

Q3: How does dual-wavelength attenuation asymmetry complicate power budget calibration for Extreme 60km single-fiber BiDi links?

A3: Single-mode fiber produces inconsistent attenuation loss for 1270nm and 1330nm optical signals during ultra-long-distance transmission. For SFP 10G BiDi Transceiver 60km deployed on Extreme metro links, this wavelength attenuation asymmetry leads to unbalanced power loss between uplink and downlink signal paths. Field engineers need to spend massive time on repeated debugging and power calibration to balance bidirectional signal strength, greatly increasing the technical difficulty of long-span link deployment and maintenance.

Q4: What permanent hardware damage risks do APD receivers face on Extreme compatible 10G BiDi 60km transceivers?

A4: The high-sensitivity APD receiving chip inside SFP 10G BiDi Transceiver 60km has extremely strict tolerance thresholds for input optical power and operating voltage. Sudden voltage surges from unstable Extreme device power supply or excessive instantaneous optical power input will trigger irreversible avalanche breakdown of the APD component. This destructive failure directly burns out the core receiving structure, rendering the entire optical module completely scrapped and unusable.

Q5: What hidden pseudo-link fault is caused by APD receiver over-saturation on Extreme 60km BiDi transmission links?

A5: When the input optical power of SFP 10G BiDi Transceiver 60km exceeds the receiver saturation threshold but does not reach the damage limit, the APD chip will fall into a signal blinding state. Although the module hardware remains intact and the Extreme switch port displays normal Link Up status, the receiver cannot accurately identify and decode optical signals. This creates a typical soft fault with zero business data throughput, which is difficult to detect through conventional network monitoring means.

Q6: How does chromatic dispersion induce bit error faults on 60km long-distance 10G BiDi links for Extreme networks?

A6: Standard G.652 single-mode fiber suffers severe chromatic dispersion interference beyond 40km during 10G high-speed transmission. For full-span 60km deployment of SFP 10G BiDi Transceiver 60km, dispersion will cause inter-symbol interference, distorting optical pulse signals. Even with sufficient optical power margin to support physical link activation, serious bit error rate elevation will occur, resulting in abnormal data transmission failure of "normal optical power but invalid business traffic" on Extreme long-haul links.

Q7: Why PMD interference on legacy fiber leads to elusive intermittent packet loss for Extreme 60km BiDi links?

A7: Aged legacy fiber pipelines widely used in traditional Extreme network renovation have prominent polarization mode dispersion characteristics. During 60km ultra-long transmission ofSFP 10G BiDi Transceiver 60km, PMD will stretch and deform optical pulses, generating completely random and non-repetitive packet loss problems. This type of intermittent fault has no fixed occurrence rules, making it one of the most difficult hidden hazards to troubleshoot and eliminate for Extreme enterprise backbone network operation teams.

Q8: Why 10G BiDi module rate downgrade deployment on 25G/100G Extreme high-density ports is unstable?

A8: New-generation Extreme 25G/100G high-density switch ports are optimized for dual-fiber multi-rate transmission architecture, with poor adaptive compatibility for single-fiber BiDi rate reduction scenarios. Most high-speed ports cannot stably lock the 10G low-speed rate required by SFP 10G BiDi Transceiver 60km. Even if forced rate adaptation is completed manually, frequent clock synchronization anomalies and signal jitters will occur, leading to persistent link flapping and unstable business transmission.

Q9: Why FEC error correction function cannot repair degraded Extreme 60km BiDi long-haul link faults?

A9: Standard 10G Extreme switch ports do not support universal sub-layer forward error correction protocols applied in 25G/100G high-speed transmission scenarios. A few devices with proprietary FEC functions will generate obvious transmission latency after enabling error correction. For long-distance private line services with strict low-latency SLA standards, the additional delay will damage service quality and cannot fundamentally solve the marginal power attenuation and signal distortion faults of SFP 10G BiDi Transceiver 60km long-span links.

Q10: Why high-power 60km BiDi modules cause overheating failures on Extreme security firewall ports?

A10: Extreme core switches are equipped with high-power heat dissipation systems and spacious chassis ventilation structures, while security firewalls adopt compact dense-port layout with limited internal air circulation. The high-power SFP 10G BiDi Transceiver 60km consumes 1.5W to 2W power during continuous operation. Long-term heat accumulation in narrow firewall port cages cannot be dissipated effectively, triggering hardware overheating, network card suspension and intermittent link offline faults in Extreme security transmission systems.

Q11: Why fiber fusion splicing and cutover maintenance take longer for Extreme 60km BiDi single-fiber links?

A11: Minor 0.2dB attenuation loss generated by fiber fusion splicing has negligible impact on short-distance network links, but it is extremely fatal for 60km long-span transmission with tight power budget margins. The precise calibrated power tolerance of SFP 10G BiDi Transceiver 60km cannot accommodate extra splicing loss. Maintenance teams need to repeatedly polish, cut and re-splice fiber joints to meet strict loss standards, greatly prolonging Extreme network cutover construction cycles and occupying limited maintenance windows.

Q12: Why frequent physical plugging causes permanent performance degradation of Extreme compatible 10G BiDi 60km modules?

A12: The internal micro WDM filter component of SFP 10G BiDi Transceiver 60km is assembled with micron-level precision positioning, featuring extremely high structural sensitivity. Frequent plugging and unplugging or rough physical operation will generate mechanical extrusion stress, slightly offsetting the precise position of the internal filter. This irreversible structural deviation will damage the module's wavelength separation and filtering performance, leading to continuous signal attenuation and reduced stability of Extreme long-haul single-fiber links.

 

Packaging & Custom OEM Solutions

Each module ships individually sealed in ESD-safe packaging, protected from static from our warehouse to your shelf—and ready to ship on receipt of order. Volume buyers and system integrators also unlock our full OEM program: custom logos, private labeling, and branded packaging, all designed to help you build and protect your own brand.
HYTOPTODEVICE 10Gbase-bx bidi transceiver  custom packaging


Why Network Engineers Choose HYTOPTODEVICE

HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.

  • Up to 70% cost savings vs OEM, transparent pricing & flexible bulk rates, supported quality returns
  • 100% real-device compatible with Cisco, Huawei,Dell,Juniper, and Arista
  • ISO 9001:2015 Shenzhen factory, full lineup: 1.25G/10G/25G/40G/100G/200G/400G/800G/1.6T transceivers
  • Ample stock, fast global DHL/FedEx shipping in 3–5 working days
  • Free pre-sales engineering support for custom EEPROM  & private label firmware
  • Real switch test videos available for pre-purchase review; inspection & shipping videos provided per order 


“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia


Quality Certification & Compliance

 At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.

We adhere to rigorous standards for our SFP modules and network solutions:

  • ISO 9001: Certified quality management and production consistency.

  • CE & FCC: Fully compliant for seamless Global Market Access.

  • RoHS: Committed to environmental responsibility and hazardous material control.

  • Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.

Certified Quality. Global Standards. Guaranteed Performance.


hytoptodevice 10g sfp+ bidi transceiver testing certification

Rigorous Industrial Product Testing

   hytoptodevice check device and equiptment for optical transceiver module

100% 3rd Party Compatible
testing device for hytoptodevice 10g sfp+ bidi optical module
Partial Test Demonstration
hytoptodevice testing devices for compatibility of sfp+ bidi 10g optical module

Others
application chart for hytoptodevice compatible optical modulehytoptodevice 10g bidi sfp+ 60km module for product chart

  • 
Extreme compatible 10GB-BX60-D module from hytoptodevice
  • 
10GB-BX60-D sfp+ bidi 60km transceiver
  • 1330nm TX 1270nm RX SFP 10G BiDi Transceiver 60km internal structure shot
  • Bulk wholesale SFP 10G BiDi Transceiver 60km for Extreme Networks switches from hytoptodevice
  • DDM-supported paired SFP 10G BiDi Transceiver 60km high-precision detail display

Download