Product Detail:
Aruba R9B41A Compatible 400G QSFP-DD SR8 PAM4 Optical Transceiver Module | HYTOPTODEVICE
Unlock high-speed data center performance with the HYTOPTODEVICE 400G QSFP-DD SR8 PAM4 optical transceiver module. This HYTOPTODEVICE 400G SR8 transceiver is fully compatible with the Aruba R9B41A model and designed for short-range 400G Ethernet applications.Operating at 850nm over OM4 multimode fiber (MMF), it supports data rates up to 425Gbps and reaches up to 100 meters using an MTP/MPO-16 connector. Built with advanced PAM4 modulation and a high-performance DSP chip, this QSFP-DD form factor module ensures reliable, low-power, and high-density connectivity.The HYTOPTODEVICE 400G SR8 transceiver is fully compliant with industry standards, including the QSFP-DD MSA, IEEE 802.3bs, and 400GAUI-8/CEI-56G-VSR-PAM4 specifications. Ideal for hyperscale data centers, cloud networking, and high-performance computing environments
Compatibility and Supported Devices
The HYTOPTODEVICE Aruba R9B41A pluggable transceiver is rigorously tested and firmware-optimized for seamless integration with:
-
Aruba CX 9300 Switch Series: 9300-32D (High-density 400G spine/leaf).
-
Aruba CX 10000 Switch Series: Distributed Services Switches with 400G uplinks.
-
Aruba CX 8325 / 8400 Series: When equipped with 400G expansion modules or line cards.
-
HPE ProLiant Servers: Compatible with 400G QSFP-DD NICs installed in HPE Gen10 Plus and Gen11 servers.
Primary Application Scenarios
-
Enterprise Core Upgrades: Enabling 400G backbone speeds within campus or data center cores.
-
High-Density Spine-Leaf: Serving as the primary short-reach (100m) interconnect for next-generation Aruba-based fabrics.
-
400G to 2x200G or 8x50G Breakout: The 8-lane design allows for high-density breakout to legacy 50G or 200G nodes using MPO-16 breakout cables.
-
AI & Storage Networking: Providing low-latency, high-throughput links for NVMe-over-Fabrics (NVMe-oF) and AI training workloads.
Key Product Parameters
| Aruba Compatible |
R9B41A |
Vendor Name |
HYTOPTODEVICE |
| Form Factor |
QSFP-DD |
Max Data Rate |
425Gbps |
| Wavelength |
850nm |
Max Distance |
70m on OM3/100m on OM4 |
| Modulation Format |
PAM4 |
Host Required |
FEC |
| Connector |
MTP/MPO-16 |
Voltage Supply |
3.3V |
| Cable Type |
MMF |
DDM Support |
Yes |
| TX Power |
-6.5~+4.0dBm |
Receiver Sensitivity |
< -7.9dBm |
| Transmitter Type |
VCSEL 850nm |
Receiver Type |
PIN |
| Maximum Power |
< 10W |
Operation Temperature |
0 to 70°C (32 to 158°F) |
| Application |
400G Ethernet, Data Center Interconnect, Infiniband Interconnects |
Protocols |
QSFP-DD MSA, CMIS 4.0, IEEE 802.3cd |
Connectivity Solutions(Applications):
Scenarios 1:400G Switch Link 400G Switch

Scenarios 2:400G Switch Link 50G Switch

Scenarios 3:400G Switch Link 200G NIC

FAQ for Aruba R9B41A Compatible QSFP-DD Transceiver Modules
Q1:What is QDD-400G-SR8? A:The 400G QSFP-DD SR8 is a hot pluggable optical transceiver module with a speed of 400Gbps, a wavelength of 850nm, and a transmission distance of up to 100m with OM4 MMF. It is ideal for data centre, 400G Ethernet and Infiniband Interconnects.
Q2:What is the maximum transmission distance of the 400G QSFP-DD SR8 transceiver?A:HYTOPTODEVICE QSFP-DD 400G SR8 module supports the maxium transmitting distance of up to 100m with OM4 MMF.
Q3:What fiber connector is required for the Aruba R9B41A ?A:The 400G QSFP DD SR8 module uses an MPO-16/APC connector. It is very important for 400G/800G MMF links to use the APC (Angled Physical Contact) polish. that can minimize back-reflection and maintain signal quality.
Q4:How does this differ from the 400G-DR4 or SR4 modules?A:DR4 is for single-mode fiber (500m), the SR8 is a short-reach (100m) multimode solution. Unlike the SR4 (4-lane), the 400G QSFP-DD SR8 uses 8 parallel lanes, providing better granularity for 50G/100G breakout applications in high-density AI clusters.
Q5:Does the HYTOPTODEVICE QSFP-DD-400G-SR8 support breakout to 50G?A:Yes. The 400G QSFP-DD SR8 utilizes parallel SR8 architecture, supporting 8x50G breakout. that allows you to connect one 400G OSFP port to eight separate 50G SFP56 SR ports with an MPO-16 breakout cable. 400G QSFP-DD SR8 manufacturer china HYTOPTODEVICE support breakout to 50G.
Q6:Where to buy 400G QSFP DD SR8 optical transceiver?A:There are many manufacturers that produce and sell 400G fiber optical modules, but 400G QSFP-DD SR8 manufacturer china HYTOPTODEVICE is the excellent provider: a source factory, fully controllable process, reliable performance, 100% compatible, sufficient inventory, fast delivery, and quick response.
Q7:The link is "Up" but I have high packet loss. Why? A:There could be two reasons,1. Dirty connectors:tiny dust particles can obstruct signal transmission. Please use fiber optic cleaner to clean the connector. 2. Fiber optic cable bending: avoid severe bending of the fiber optic cable.
Q8:Is the 400G QSFP-DD SR8 backward compatible with lower-speed modules,such as 100G?A:Yes,The 400G SR8 is backward compatible with lower-speed optical transceivers, such as 200G,100G and 50G, but the performance will be reduced.
Q9:How do HYTOPTODEVICE ensure 400G QSFP-DD SR8 module compatibility with network switch?A:Ensuring 100% compatibility, optical modules must be coded to match the switch's requirements. Source-factory HYTOPTODEVICE was equipped with various high-speed switch,the brands include such as Cisco,NVIDIA,Huawei. highly professional in coding equipment for various brands to ensure they are recognized and running in your device.
Q10:Is QDD-400G-SR8 hot-swappable?A:HYTOPTODEVICE fiber transceiver modules are hot-pluggable, hot Pluggable QSFP-DD MSA Compliant.you can plug or unplug the optical transceiver, while the device is powered on without damaging the hardware.
Q11:Why Choose HYTOPTODEVICE for Huawei Aruba R9B41A ?A: High-Speed Optical Transceiver Manufacturer China HYTOPTODEVICE ensures that the QDD-400G-SR8 is coded and tested for full compatibility with major switch vendors (such as Cisco, Juniper, NVIDIA/Mellanox, and huawei). They verify the EEPROM settings to ensure "plug-and-play" functionality without port-recognition errors.
Q12:Does it use MPO-12 or MPO-16?A:The 400G QSFP-DD SR8 must use MPO-16 (APC) connectors. The reason is that SR8 uses 8 channels for transmission (Tx) and 8 channels for reception (Rx) (a total of 16 optical fibers). and MPO-12 fiber optic cables were not suitable.
Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 500,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
- 100% MSA-compliant modules with Cisco, Huawei,Dell,Juniper, and Arista compatibility
- ISO 9001:2015 certified manufacturing facility in Shenzhen
- Average lead time of 3–5 business days with DHL/FedEx express options
- Dedicated pre-sales engineering support for custom configurations
- Actual hardware,actual switches,actual results.we publish compatibility test video,eliminate compatibility anxiety. you can watch before you buy.
- We can provide inspection and shipping videos to make you feel as if you are right here with the product.
"We replaced 200 Cisco-branded SFPs with HYTOPTODEVICE equivalents across our spine layer — zero compatibility issues, 40% cost reduction."— Network Architect, Tier-2 ISP, Germany
Quality Certification & Compliance:
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final inspection, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
-
ISO 9001: Certified quality management and production consistency.
-
CE & FCC: Fully compliant for seamless Global Market Access.
-
RoHS: Committed to environmental responsibility and hazardous material control.
-
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.

Rigorous Industrial Product Testing:

100% 3rd Party Compatible:

Partial Test Demonstration:

Others:



