| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | QSFP-4SFP10G-CU50CM | |
| 2 | Arista Networks | CAB-Q-S-0.5M | |
| 3 | Juniper | QFX-QSFP-DACBO-50CM | |
| 4 | Brocade | 40G-QSFP-4SFP-C-0105 | |
| 5 | Dell | 332-1365 | |
| 6 | Intel | X4DACBL50 | |
| 7 | NVIDIA/Mellanox | MC2609130-050 | |
| 8 | IBM | BN-QS-SP-CBL-50CM |
| IBM Compatible |
BN-QS-SP-CBL-50CM
|
Vendor Name | HYTOPTODEVICE |
| Connector | QSFP+ to 4 x SFP+ | Max Data Rate | 40Gbps |
| Cable Length | 0.5m (1.6ft) | Wire AWG | AWG 30 |
| Cable Type | Passive Twinax | Power Consumption | ≤0.5W |
| Media | Copper | Operation Temperature | 0~ 70 °C (32 to 158°F) |
| Jacket Material | PVC(OFNR) | Protocols | SFF-8436, SFF-8431 and QSFP+ MSA |
| Minimum Bend Radius | 21mm | Application | 40G InfiniBand 8x DDR, 4x QDR, 10/40 Gigabit Ethernet, Fibre Channel |
Usage Guidelines & Best Practices
Mandatory Port Breakout Configuration: Ensure the host QSFP+ port supports channelization. Enable breakout mode (4x10G) via the switch CLI before connecting the cable.
Cabling Requirements: Do not exceed the minimum 21mm bend radius, avoid sharp folding, heavy extrusion or long-term tension on the cable assembly.
Port Installation Standard: Do not mix this breakout DAC with straight QSFP+ to QSFP+ DAC configuration.
Hot‑swap rule:Never pull or tug directly on the individual breakout legs. Always use the integrated pull-tab or bale latch when inserting or removing connectors.
Operating Environment: 0‑70℃, indoor cabinet deployment only.
For detailed operation instructions, please refer to the User Guide.
Full Compatibility List & Supported Devices
Built on universal MSA open standards, this 40G QSFP+ to 4 x 10G SFP+ passive breakout DAC cable can interoperate with mainstream network brands including Arista, Intel, Juniper, Dell, NVIDIA Mellanox and IBM, for mixed-vendor rack stacking and server fabric expansion.




Q1: What IBM switch firmware versions work well with this BN-QS-SP-CBL-50CM compatible QSFP+ 40G to 4x10G Breakout Cable? A: It runs stably on mainstream IBM BNT EN4093 firmware releases. HYTOPTODEVICE pre-tests each batch against standard IBM firmware, reducing compatibility risks for solution providers placing stock orders.
Q2: Can I use this QSFP+ 40G to 4x10G Breakout Cable for IBM switch stacking alongside breakout mode? A: No, IBM BNT stacking mode locks the QSFP+ port as a single 40G port. Breakout and stacking functions cannot activate together, so distributors should plan port usage before purchase.
Q3: What is the expected service lifespan of stocked QSFP+ 40G to 4x10G Breakout Cable for IBM data center deployments? A: Under proper rack operating conditions, this passive twinax cable delivers 8+ years of reliable service. HYTOPTODEVICE builds each unit with high-grade copper to support long-term stock for value-added resellers.
Q4: Does ordering this IBM compatible QSFP+ 40G to 4x10G Breakout Cable require a minimum MOQ for system integrators? A: HYTOPTODEVICE supports low MOQ orders for this breakout cable. We keep ready inventory so small and mid-size IBM project buyers can place flexible purchase orders.
Q5: Can I mix this QSFP+ 40G to 4x10G Breakout Cable with IBM original transceivers in the same IBM Flex chassis? A: Yes, IBM chassis ports handle DAC and optical transceivers independently. As long as breakout mode is configured correctly, integrators can combine media types in one chassis.
Q6: What signal loss margin does this 0.5m QSFP+ 40G to 4x10G Breakout Cable reserve for IBM 40GBASE-CR4 links? A: This short 0.5m twinax design maintains ample signal margin for 40GBASE-CR4. Low signal loss makes it a reliable stocking choice for IBM storage networking buyers.
Q7: Will the IBM switch trigger log warning messages after I install this pre-coded QSFP+ 40G to 4x10G Breakout Cable? A: Minor informational logs may appear rarely; critical link-blocking alerts are eliminated via our IBM EEPROM profile. HYTOPTODEVICE pre-flash programming eases troubleshooting for IT contractors.
Q8: Can this QSFP+ 40G to 4x10G Breakout Cable be reused if I migrate my IBM workload to a new Flex chassis? A: Yes, passive DAC cables are reusable hardware. If your new IBM hardware needs different coding, HYTOPTODEVICE offers EEPROM re-programming service for existing stocked cables.
Q9: Which IBM storage networking use cases fit this QSFP+ 40G to 4x10G Breakout Cable best? A: It is ideal for short-range iSCSI storage interconnects inside IBM Flex and Spectrum clusters. Many storage resellers purchase this cable to expand 10G port density on IBM storage switches.
Q10: What packaging options are available when I buy bulk QSFP+ 40G to 4x10G Breakout Cable for IBM project rollout? A: HYTOPTODEVICE provides anti-static individual packing and bulk carton packing. Custom labeling with your reseller brand is available for large procurement orders of this breakout cable.
Q11: Does this QSFP+ 40G to 4x10G Breakout Cable support IEEE 802.3bb flow control for IBM lossless Ethernet networks? A: Yes, the passive copper media does not block pause frame flow control. It fully supports PFC and IEEE flow control settings configured on IBM BNT switches for HPC buyers.
Q12: Can this QSFP+ 40G to 4x10G Breakout Cable sustain stable links under IBM chassis high-temperature airflow? A: Its rated operating range covers 0°C to 70°C. Passive DAC generates no heat, so it works reliably under normal IBM chassis thermal conditions for stocked deployments.
Q13: What inspection reports can HYTOPTODEVICE supply with purchased QSFP+ 40G to 4x10G Breakout Cable shipments? A: We can provide batch TDR test reports and RoHS certificates upon request. This documentation helps wholesalers meet audit requirements for IBM data center tender projects.
Q14: Is this QSFP+ 40G to 4x10G Breakout Cable eligible for cross-border export shipment to IBM overseas branch sites? A: Yes, it meets global RoHS and REACH standards without restricted materials. HYTOPTODEVICE supports export documentation for international distributors purchasing this IBM compatible cable.
Q15: What should I check first if one of the four 10G breakout lanes drops after installing the QSFP+ 40G to 4x10G Breakout Cable on IBM switches? A: Start by checking SFP+ connector seating and IBM port breakout CLI settings. Lane faults most often come from loose insertion or missing channelization config for newly purchased units.
Packaging & Custom OEM Solutions
ESD Protection & Fast Shipping: Every transceiver is sealed in an ESD-safe bag and ready for same-day dispatch from stock.
Custom OEM & Branding: We provide logo printing, private labeling, and custom packaging to help distributors and integrators build their brand—no factory investment required.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.




