• hytoptodevice 1.25g DWDM SFP TRANSCEIVER module 80km smf for cisco switch
  • hytoptodevice 1000BASE-DWDM fiber optical transceiver 80km smf
  • cisco compatible 1.25G 1000BASE-DWDM 80KM optical transceiver bulk supply
  • hytoptodevice 1.25G DWDM MUX/DEMUX multi-channel fiber aggregation solution for Dwdm transceivers
  • hytoptodevice 1.25g DWDM SFP TRANSCEIVER module 80km smf for cisco switch
  • hytoptodevice 1000BASE-DWDM fiber optical transceiver 80km smf
  • cisco compatible 1.25G 1000BASE-DWDM 80KM optical transceiver bulk supply
  • hytoptodevice 1.25G DWDM MUX/DEMUX multi-channel fiber aggregation solution for Dwdm transceivers

Cisco C49 DWDM‑SFP‑3819‑80 Compatible 1.25G DWDM SFP Transceiver Module | 1000BASE-DWDM 1538.19nm 80km 100GHz | HYTOPTODEVICE

Source Cisco C49 DWDM‑SFP‑3819‑80 compatible 1.25G 1538.19nm 80km 100GHz DWDM SFP transceiver for long‑haul metro optical transport builds. Ready‑to‑ship DWDM optical transceiver for network solution vendors and wholesale partners. TEC‑stabilized cooled DFB laser, full DDM digital diagnostic support, custom EEPROM imprinting available, support pre‑ship sample evaluation and large‑scale project sourcing for optical networking deployments.
CH Cisco Compatible P/N  CH Cisco Compatible P/N
CH37 DWDM‑SFP‑4772‑80 CH50 DWDM‑SFP‑3740‑80
CH38 DWDM‑SFP‑4692‑80 CH51 DWDM‑SFP‑3661‑80
CH39 DWDM‑SFP‑4612‑80 CH52 DWDM‑SFP‑3582‑80
CH40 DWDM‑SFP‑4532‑80 CH53 DWDM‑SFP‑3504‑80
CH41 DWDM‑SFP‑4453‑80 CH54 DWDM‑SFP‑3425‑80
CH42 DWDM‑SFP‑4373‑80 CH55 DWDM‑SFP‑3347‑80
CH43 DWDM‑SFP‑4294‑80 CH56 DWDM‑SFP‑3268‑80
CH44 DWDM‑SFP‑4214‑80 CH57 DWDM‑SFP‑3190‑80
CH45 DWDM‑SFP‑4135‑80 CH58 DWDM‑SFP‑3112‑80
CH46 DWDM‑SFP‑4056‑80 CH59 DWDM‑SFP‑3033‑80
CH47 DWDM‑SFP‑3977‑80 CH60 DWDM‑SFP‑2955‑80
CH48 DWDM‑SFP‑3898‑80 CH61 DWDM‑SFP‑2877‑80
CH49 DWDM‑SFP‑3819‑80 CH62
Description

Cisco C49 DWDM‑SFP‑3819‑80 Compatible 1.25G DWDM SFP Transceiver Module | 1000BASE‑DWDM 1538.19nm 80km Bulk Wholesale

Product Overview

HYTOPTODEVICE C49 DWDM SFP serves as form‑fit, function‑equivalent drop‑in alternative to Cisco DWDM‑SFP‑3819‑80, adhering to ITU‑T 100GHz C‑band frequency grid with central operating wavelength of 1538.19nm. It sustains error‑free 80km signal transmission across standard G.652.D single‑mode fiber. This optical unit is widely adopted by network solution vendors and wholesale partners for metro DWDM infrastructure erection, service scaling, and capacity boosting for already‑running optical networks.
Built around a TEC‑cooled DFB laser assembly, this transceiver maintains rigorous wavelength precision to minimize inter‑channel crosstalk under dense wavelength multiplexing conditions. Its full‑load power draw stays below 2W. Factory‑configured Cisco‑oriented EEPROM profile eliminates “unrecognized transceiver” warning prompts upon hot‑plug insertion. Integrated SFF‑8472 DDM monitoring grants field technicians real‑time visibility over key optical parameters during on‑site commissioning and routine network health checks. We accommodate small‑lot pre‑validation sample orders alongside high‑volume project‑based sourcing to satisfy varied procurement scenarios.

Key Technical Specifications

 Cisco Compatible DWDM-SFP-3819-80 Vendor Name HYTOPTODEVICE
Form Factor SFP Max Data Rate 1.25Gbps
Wavelength 1538.19nm Max  Distance 80KM
Connector Duplex LC Transmitter Type DWDM DFB (Cooled)
Cable Type SMF Receiver Type PIN
TX Power 0~+5dBm Receiver Sensitivity < -26.0dBm
Power Consumption ≤2W Receiver Overload -3.0dBm
Protocols SFP MSA, SFF-8472 Operation Temperature 0 to 70°C (32 to 158°F)

Usage Guidelines & Best Practices

  • Fiber & Connector: Use OS2 single-mode fiber with LC-UPC connectors only (LC-APC strictly prohibited). Match transceiver wavelength with your DWDM ITU channel.

  • Optical Attenuation (Crucial): Never direct-connect! Since Tx reaches up to +5 dBm, install a 10–15 dB inline attenuator at the Rx port during lab/short-link testing to keep input power below -3 dBm and prevent receiver burnout.

  • Architecture: Built with a Cooled DFB (TEC) transmitter and a PIN receiver (sensitivity ~ -24 dBm, 24 dB link budget).

  • Thermal Management: Operating temp: 0°C to 70°C. Proper airflow is essential for TEC wavelength locking to prevent link drops.

  • Handling: Supports hot-swapping via bail latch. Always clean LC fiber end-faces before connection.


Full Compatibility List & Supported Network Hardware

1. Supported Hardware & Firmware
 
Custom Cisco‑specific EEPROM signature eliminates alarms and port lockdown. No extra configuration or firmware upgrade is required for plug‑and‑play deployment across supported Cisco enterprise and carrier‑grade hardware.

Fully Compatible Cisco Platforms:
  • Cisco Catalyst 3850, 9200, 9300 Series enterprise switches
  • Cisco ISR 4000‑series multi‑service branch routers
  • Cisco ASR 1000‑series carrier backbone routers
  • Cisco ONS optical transport platforms supporting 100GHz DWDM SFP
  • All Cisco devices accepting original DWDM‑SFP‑3819‑80 transceivers

2. Multi-Brand Cross Compatibility

Compliant with universal SFP MSA specifications, this C49 DWDM SFP runs error‑free on Huawei, H3C, Juniper, MikroTik and other mainstream network hardware. Custom firmware adaptation is available for complex multi‑vendor DWDM environments.

3. Free Value-Added Services

HYTOPTODEVICE offers competitive bulk pricing for resellers, system integrators and data center contractors. We provide free special compatible EEPROM reprogramming for all bulk orders.
Available options include private label printing, custom packaging and deployment consulting. All modules pass optical calibration, temperature cycling and 72-hour full-traffic burn-in. Large-volume orders enjoy tiered discounts to reduce project CAPEX.

Primary Application Scenarios

• Metro DWDM Ring: Dedicated C49 wavelength realizes single-fiber multiplexing to reduce carrier fiber investment
• Wireless Cell Backhaul: Passive 80km gigabit connectivity lowers remote site operation expenses
• Enterprise Cross-Branch: Low-cost private fiber for inter-office data & real-time video transmission
• MAN Service Aggregation: Isolated wavelengths avoid service cross-interference and boost network stability
• Industrial IoT Monitoring: Anti-interference optical design for long-distance smart city & factory data links
• Legacy Network Upgrade: Add C-band wavelengths without full infrastructure overhaul

Connectivity Solutions(Applications)

1.
Direct Cabling DWDM Solution
Pair C49 module with standard DWDM multiplexers & demultiplexers to carry multi-service signals on single fiber, simplify field wiring for medium-short gigabit spans.



2. 80km Long-Haul DWDM Solution

Match EDFA optical amplifiers to offset natural fiber attenuation, stabilizing DWDM signal for intercity carrier core backhaul networks.


The Core Feature

1. Low-Power Data Center Efficient Connectivity

Ultra-low power design reduces power consumption and heat generation. The optimized single-fiber structure simplifies data center cabling, enabling cost-effective and stable gigabit Ethernet transmission.

1G Data Center Connectivity low power single-fiber Gigabit Ethernet DWDM SFP solution


2.
Verified Host Interoperability for Cisco Devices

Calibrated firmware supports zero-alarm plug-and-play for Huawei, Cisco and other mainstream devices. It solves multi-brand compatibility problems and adapts to hybrid network deployment.
Verified multi-vendor interoperability for  Cisco  DWDM SFP transceiver

3.Rigorous Testing, Uncompromising Reliability

Integrating precise wavelength locking, stable 80km long-haul transmission and multi-scenario adaptability, this module forms a complete gigabit DWDM solution. It fully meets diversified networking demands for carrier metro backhaul and enterprise long-distance interconnection.

Comprehensive 1.25G 80km C17 DWDM networking solution for carrier and enterprise deployment


FAQ

Q1: Is sourcing third‑party compatible DWDM SFP safe for telecom tender projects? Will it void original network hardware warranty?
A: Across most global commercial territories, MSA‑compliant compatible transceivers will not invalidate host‑device warranty. If your network hardware enforces strict OEM identity lock‑in for tender projects, our free‑of‑charge EEPROM adjustment can suppress system warning alerts and reduce warranty‑relevant risks for your sourced units. Get in touch with our sales team for project‑tailored sourcing recommendations.

Q2: Can I acquire pre‑imprinted C49 DWDM SFP matched for legacy or special‑spec network hardware for my wholesale partner client project?
A: Our technical team provides custom EEPROM re‑imprinting service for project‑focused buyers. Submit full hardware model specifications before placing bulk tender sourcing orders. We deliver personalized configuration within one business day plus round‑the‑clock technical support for project‑related orders.

Q3: Do C49 DWDM SFP comply with MSA requirements when sourcing large batches for telecom network tender bids?
A: Every C49 unit strictly adheres to SFP MSA mechanical, electrical and optical specifications and supports full SFF‑8472 DDM diagnostic functions. Consistent industry‑standard performance ensures reliable cross‑hardware interoperability for your project‑sourced batch units.

Q4: What link budget can the 1538.19nm C49 DWDM SFP deliver for DWDM tender project assessment?
A: This transceiver provides total 24 dB link budget derived from 0~+5dBm transmit output and ‑24dBm receiver sensitivity, supporting full‑range 80km transmission over standard single‑mode fiber. It serves as key performance benchmark for network solution vendors and wholesale partners evaluating project link margin allowance.

Q5: For multi‑year non‑stop‑operating telecom metro DWDM networks, can sourced C49 modules hold steady 1538.19nm wavelength output?
A: On‑board TEC thermoelectric hardware stabilizes laser chip working temperature, complemented by factory‑level wavelength calibration. This mechanical‑electronic setup restrains long‑term wavelength drift and maintains tight 100GHz channel spacing for your long‑term deployed sourced units.

Q6: During dense DWDM tender‑project deployment, will cumulative insertion loss from MUX/DEMUX hardware trigger full fiber link failure?
A: The built‑in 24 dB link margin tolerates ordinary insertion loss brought by DWDM multiplexer hardware. When overall link attenuation exceeds project‑allowed margin, deploying EDFA amplifiers can restore usable signal magnitude.

Q7: What is the safe minimum unamplified fiber span for sourced C49 DWDM‑SFP‑3819‑80 module? Am I required to source extra optical attenuators for short‑link application scenarios?
A: Safe minimum unamplified fiber distance for this 80km‑rated DWDM transceiver is 15 km. For shorter fiber runs within your tender project, you must deploy 10‑15 dBm fixed optical attenuators to avoid receiver optical saturation and permanent port hardware damage.

Q8: Are surge‑protection circuits integrated within C49 DWDM SFP for high‑density telecom rack operating environments?
A: Embedded protective circuits shield laser and receiver chips against over‑voltage, over‑current and ESD surges generated during hot‑swap plug‑in, enhancing long‑term operational reliability for bulk‑sourced units housed inside high‑density telecom equipment racks.

Q9: Why does active thermal stabilization matter for sourced C49 modules deployed inside high‑density telecom DWDM metro networks?
A: Laser emitting wavelength shifts noticeably with temperature swings. On‑board TEC dynamically modulates laser operating temperature to lock onto the 1538.19nm ITU‑T channel and mitigate crosstalk between densely‑packed DWDM wavelength channels for your sourced network hardware.

Q10: What adverse outcomes will occur if sourced C49 modules continuously run above maximum rated temperature at telecom field sites?
A: Persistent overheating causes wavelength offset, elevated bit‑error ratio and fluctuating DDM monitoring readings. Extended high‑temperature operation accelerates laser component ageing. For high‑temperature‑site tender projects, implement rack cooling infrastructure or select our industrial extended‑temperature variant.

Q11: After sourcing C49 DWDM SFP for managed‑switch‑based DWDM tender projects, how can field operators retrieve real‑time DDM diagnostic data?
A: Live metrics covering transmit power, receive power, module internal temperature and supply voltage can be natively accessed via switch CLI transceiver commands or web‑based management interfaces; no third‑party software installation is needed for your sourced hardware.

Q12: How are bulk‑tender‑sourced C49 DWDM SFP packaged for cross‑border network‑solution‑vendor and wholesale‑partner project shipment?
A: Each sourced C49 transceiver is fitted with LC dust protective caps upon passing comprehensive optical‑performance testing, individually sealed inside anti‑static moisture‑resistant bags with shock‑absorbing foam padding, safeguarding fiber end‑faces from scratches, dust and oil contamination for international tender‑project delivery.

Why Network Engineers Choose HYTOPTODEVICE

HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
  • Up to 70% cost savings vs OEM, transparent pricing & flexible bulk rates, supported quality returns
  • 100% real-device compatible with Cisco, Huawei,Dell,Juniper, and Arista
  • ISO 9001:2015 Shenzhen factory, full lineup: 1.25G/10G/25G/40G/100G/200G/400G/800G/1.6T transceivers
  • Ample stock, fast global DHL/FedEx shipping in 3–5 working days
  • Free pre-sales engineering support for custom EEPROM  & private label firmware
  • Real switch test videos available for pre-purchase review; inspection & shipping videos provided per order

“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia


Quality Certification & Compliance

 At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.

We adhere to rigorous standards for our SFP modules and network solutions:

  • ISO 9001: Certified quality management and production consistency.

  • CE & FCC: Fully compliant for seamless Global Market Access.

  • RoHS: Committed to environmental responsibility and hazardous material control.

  • Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.

Certified Quality. Global Standards. Guaranteed Performance.




Rigorous Industrial Product Testing

   hytoptodevice check device and equiptment for optical transceiver module

100% 3rd Party Compatible
hytoptodevice 100g qsfp28 sr4 replacement
Partial Test Demonstration
hytoptodevice compatible optical transceiver module for ethernet,data center

Others
HYTOPTODEVICE 100G QSFP28 TRANSCEIVER sr4 application for data center,ethernet

 



 

 

 

  • hytoptodevice 1.25g DWDM SFP TRANSCEIVER module 80km smf for cisco switch
  • hytoptodevice 1000BASE-DWDM fiber optical transceiver 80km smf
  • cisco compatible 1.25G 1000BASE-DWDM 80KM optical transceiver bulk supply
  • hytoptodevice 1.25G DWDM MUX/DEMUX multi-channel fiber aggregation solution for Dwdm transceivers

Download